–178–Q0800C/CVD875 SERIES REMOTE AIR COOLEDNOTE: These characteristics may vary depending onoperating conditions.CYCLE TIMES24-HOUR ICE PRODUCTIONOPERATING PRESSURESFreeze Time + Harvest Time = Cycle TimeAir Temp.EnteringCondenser°F/°CFreeze TimeHarvestTimeWater Temperature °F/°C50/10.0 70/21.1 90/32.2-20 to 70/-29 to 21.1 9.4-10.8 10.5-12.1 11.4-13.1.75-2.580/26.7 9.5-11.0 10.7-12.3 11.4-13.190/32.2 10.3-11.9 11.2-12.9 12.1-13.8100/37.8 11.2-12.9 12.3-14.1 13.3-15.21Times in minutes.Air Temp.EnteringCondenser°F/°CWater Temperature °F/°C50/10.0 70/21.1 90/32.2-20 to 70/-29 to 21.1 760 690 64080/26.7 750 680 64090/32.2 700 650 610100/37.8 650 600 5601Based on average ice slab weight of 5.75-6.50 lb.2Regular cube derate is 7%.Air Temp.EnteringCondenser°F/°CFreeze Cycle Harvest CycleDischargePressurepsigSuctionPressurepsigDischargePressurepsigSuctionPressurepsig-20 to 50/-29 to 10.0 260-215 46-22 140-185 70-9570/21.1 270-220 40-23 150-190 70-10080/26.7 285-225 47-24 155-195 80-9590/32.2 295-235 52-25 165-200 85-100100/37.8 340-260 56-26 180-210 85-112110/43.3 385-300 60-28 195-230 90-115Refer to page 176.