–37–CLEANING PROCEDUREIce machine cleaner is used to remove lime scale orother mineral deposits. It is not used to remove algaeor slime. Refer to “Sanitizing Procedure” on page 39for removal of algae and slime. To initiate a cleaningcycle using Manitowoc’s Patented CleaningTechnology, use the following procedure.Step 1. Set the toggle switch to the OFF position afterice falls from the evaporator at the end of a Harvestcycle. Or, set the switch to the OFF position and allowthe ice to melt off the evaporator.Step 2. To start a cleaning cycle, move the toggleswitch to the CLEAN position. The water will flowthrough the water dump valve and down the drain. TheClean light* will turn on to indicate the ice machine isin the cleaning mode.Step 3. Wait about one minute or until water starts toflow over the evaporator.Step 4. Add the proper amount of Manitowoc IceMachine Cleaner to the water trough.*The Q1400C ice machine control board does not energize aClean light.! CautionNever use anything to force ice from the evaporator.Damage may result.QuietQube® Models Amount of CleanerQ0600C/Q0800C/SU1000C/Q1400C5 ounces (150 ml)Q1000C/QDUAL 9 ounces (270 ml)