–76–Automatic Shut-Off7. Automatic Shut-OffIce Machine Section: When the storage bin is full atthe end of a Harvest sequence, the sheet of ice cubesfails to clear the water curtain and will hold it open.After the water curtain is held open for 7 seconds, theice machine shuts off. The ice machine remains off for3 minutes before it can automatically restart.CVD® Condensing Unit: The liquid line solenoid valvecloses, allowing the refrigeration system to pumpdown. When the refrigerant pressure is low enough toopen the fan cycling pressure control,* the condenserfan motor stops. When the refrigerant pressure is lowenough to open the low-pressure control, the contactorcoil is de-energized and the compressor stops.The ice machine remains off until enough ice has beenremoved from the storage bin to allow the ice to fallclear of the water curtain. As the water curtain swingsback to the operating position, the bin switch reclosesand the ice machine restarts (steps 1-2), provided the3-minute delay period is complete.*The Q0600C ice machine does not use a fan cycle control;therefore the condenser fan motor will energize and de-energize with the compressor.