Installation Instructions Section 22-32 Part Number 000002477 3/08Installation ChecklistIs the Ice Machine level?Has all of the internal packing been removed?Have all of the electrical and water connectionsbeen made?Has the supply voltage been tested and checkedagainst the rating on the nameplate?Is there proper clearance around the ice machinefor air circulation?Has the ice machine been installed whereambient temperatures will remain in the range of35° - 110°F (2° - 43°C)?Has the ice machine been installed where theincoming water temperature will remain in therange of 35° - 90°F (2° - 32°C)?Are the ice machine and bin drains separatelyvented?Are all electrical leads free from contact withrefrigeration lines and moving equipment?Has the owner/operator been instructed regardingmaintenance and the use of Manitowoc Cleanerand Sanitizer?Has the warranty registration card been sent tothe factory?Has the ice machine and bin been sanitized?IB Only - Has the thermostat kit been installedand tested?IB Only - Is the adapter secured to thedispenser?Has the ice machine receiver service valve beenopened 100%?Does the condenser fan motor operate properlyafter start-up?Have all the refrigeration fittings and joints beenleak checked?Is the line set routed properly?Is a refrigeration oil trap (S-trap) installed if thecondenser is installed 21 to 35 feet (6 to 11m)above the ice machine head?Has the CVD® condensing unit been installed toprevent any roofing damage?Have the refrigeration lines been insulated andsecured properly to prevent vibration?Has the remote condensing unit been locatedwhere ambient temperatures will remain in therange of -20° to 130°F (-29° to 54°C)?CVD675/CVD2085 Only - The air temperaturemust be at least -20°F (-29°C) but must notexceed 120°F (49°C).Are the plastic bushings installed on the CVD®condensing unit to prevent refrigeration tubingfrom contacting the sheet metal panel?CVD1486 Only - Is the drain installed on thecondensing unit?Is the condensing unit level?