Maintenance Section 44-14 Part Number 000002477 3/08Removal from Service/WinterizationGENERALSpecial precautions must be taken if the ice machine isto be removed from service for an extended period oftime or exposed to ambient temperatures of 32°F (0°C)or below.Follow the procedure below.1. Clean and sanitize the ice machine.2. Move the ICE/OFF/CLEAN switch to OFF.3. Disconnect the electric power at the circuit breakeror the electric service switch.4. Turn off the water supply.5. Remove the water from the water trough.6. Disconnect and drain the incoming ice-making waterline at the rear of the ice machine.7. Energize the ice machine and wait one minute forthe water inlet valve to open.8. Blow compressed air in both the incoming water andthe drain openings in the rear of the ice machineuntil no more water comes out of the inlet water linesor the drain.9. Make sure water is not trapped in any of the waterlines, drain lines, distribution tubes, etc.10. Fill spray bottle with sanitizer and spray all interiorfood zone surfaces. Do not rinse and allow to air dry.11. “Frontseat” (shut off) the receiver service valves.Hang a tag on the switch as a reminder to open thevalves before restarting.CVD1486 WATER COOLED CONDENSING UNIT1. Perform steps 1-11 in previous column.2. Disconnect the incoming water and drain lines fromthe water-cooled condenser.3. Insert a large screwdriver between the bottom springcoils of the water regulating valve. Pry upward toopen the valve.Pry Open the Water Regulating Valve4. Hold the valve open and blow compressed airthrough the condenser until no water remains.! CautionIf water is allowed to remain in the ice machine infreezing temperatures, severe damage to somecomponents could result. Damage of this nature isnot covered by the warranty.SV1624