BMC Configuration User’s Guide4.4.3 Battery Controller ConfigurationThis screen displays and sets the various functions of the battery controller.Item Description Default ValueBattery Controller Configuration Battery Controller settingShutdown at power lost Select Enable/Disable of the ability to shutdownat the power failure. *1DisableShutdown delay time Set the timeout period until the shutdown will bestarted at the power failure. *2 *30Battery turn off delay time Set the timeout period until the shutdown will befinished at the power failure. *2 *30Boot after power recovery Select Enable/Disable of the ability to boot afterthe power recovery. *2 *4DisableBoot timeout after DC-ON Set the timeout period until the boot is completeafter DC-ON. *2 *3 *50*1: The POWER Switch should be configured to shutdown in the OS.*2: It is possible to set only if Shutdown at power lost is set to "Enable".*3: The battery output period may be briefer in duration than the each configured time in this item,depending on the remaining charge.*4: This item is valid only when AC-LINK is set 'Stay Off', or AC-LINK is set 'Last State' and Last State isDC-OFF.*5: This item is valid at DC-ON after the shutdown system by 'Shutdown at power lost'. (DC-ON by 'Bootafter power recovery' or manually)