4-48 System ConfigurationHOW TO CLEAR THE BMC CONFIGURATION1. Power off NEC Express5800/ft series and unplug the both power cords.2. Remove the both CPU/IO modules (0 and 1) from the NEC Express5800/ft series (see“Removing CPU/IO Module” on page 8-11).3. Make setting of jumper switch for clearing the BMC configuration of module 0.Remove the clips from the jumper pins (J57) 2-3 on CPU/IO module 0 and place them onthe jumper pins (J20) 7-8 on the CPU/IO module 0.4. Mount the CPU/IO module 0 to NEC Express5800/ft series (see “Installing CPU/IOModule” on page 8-14).5. Connect the power cord of CPU/IO module 0 only, and then press the POWER switch topower on.6. When POST is completed after the startup, press the POWER switch to power off, andthen disconnect the power cord from the outlet.7. By referring to “Removing CPU/IO Module” on page 8-11, remove the CPU/IO module 0from the server.8. Reset the jumper switch setting.Remove the clips from the jumper pins (J20) 7-8 and place them on the jumper pins (J57)2-3 on the CPU/IO module 0.9. Clear password for the CPU/IO module 1 by following the steps 3 to 8.10. By referring to “Installing CPU/IO Module” on page 8-14, install both CPU/IO moduleson the server.11. Connect both power cords.