12W415-0779 / A / 04.27.103.4 MINIMUM AIR TERMINAL LOCATION CLEARANCESINSTALLATIONSCANADA U.S.A.A 12” 12” Clearance above grade, veranda porch, deck or balcony.B 12” Δ 9” Δ Clearance to windows or doors that open.C 12” * 12” * Clearance to permanently closed windows.D 18” ** 18” ** Vertical clearance to ventilated soffits located above the terminal within a horizontal distance of 2’ fromthe centerline of the terminal.E 12” ** 12” ** Clearance to unventilated soffit.F 0” 0” Clearance to an outside corner wall.G 0” *** 0” *** Clearance to an inside non-combustible corner wall or protruding non-combustible obstructions (chimney, etc.).2” *** 2” *** Clearance to an inside combustible corner wall or protruding combustible obstructions (vent chase, etc.).H 3’ 3’ **** Clearance to each side of the centerline extended above the meter / regulator assembly to a maximumvertical distance of 15’.I 3’ 3’ **** Clearance to a service regulator vent outlet.J 12” 9” Clearance to a non-mechanical air supply inlet to the building or a combustion air inlet to any other appliance.K 6’ 3’ † Clearance to a mechanical air supply inlet.L 7’ ‡ 7’ **** Clearance above a paved sidewalk or paved driveway located on public property.M 12” †† 12” **** Clearance under a veranda, porch, deck or balcony.N 16” 16” Clearance above the roof.O 2’ †* 2’ †* Clearance from an adjacent wall including neighbouring buildings.P 8’ 8’ Roof must be non-combustible without openings.Q 3’ 3’ See chart for wider wall dimensions.R 6’ 6’ See chart for deeper wall dimensions. The terminal shall not be installed on any wall that has an open-ing between the terminal and the open side of the structure.Δ The terminal shall not be located less than 6 feet under a window that opens on a horizontal plane in a structure with three walls and a roof.* Recommended to prevent condensation on windows and thermal breakage** it is recommended to use a heat shield and to maximize the distance to vinyl clad soffits.*** The periscope requires a minimum 18 inches clearance from an inside corner.**** This is a recommended distance. For additional requirements check local codes.† 3 feet above if within 10 feet horizontally.‡ A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings.†† Permitted only if the veranda, porch, or deck is fully open on a minimum of two sides beneath the floor.†* Recommended to prevent recirculation of exhaust products. For additional requirements check local codes.12.1ANOTE: Clearances are in accordance with local installation codes and the requirements of the gas supplier.RQ MG PCOVERED BALCONY APPLICATIONSQ MINR MAXMAXR= 3 feet= 2 x feetQ ACTUAL