24W415-0779 / A / 04.27.1030.1AInstallation and servicing to be done by a qualified installer. Do not use open flame.• Move the appliance into position and secure.• If equipped with a flex connector the appliance is designed to accept a 1/2” gas supply. Without theconnector it is designed to accept a 3/8” gas supply. The appliance is equipped with a manual shut offvalve to turn off the gas supply to the appliance.• Connect the gas supply in accordance to local codes. In the absence of local codes, install to thecurrent CAN/CSA-B149.1 Installation Code in Canada or to the current National Fuel Gas Code, ANSIZ223.1 / NFPA 54 in the United States.• When flexing any gas line, support the gas valve so that the lines are not bent or kinked.• The gas line flex-connector should provide sufficient movement to permit shifting the burner assemblyon it’s side.• Check for gas leaks by brushing on a soap and water solution.! WARNINGRISK OF FIRE, EXPLOSION OR ASPHYXIATION. ENSURE THERE ARE NO IGNITION SOURCES SUCH ASSPARKS OR OPEN FLAMES.SUPPORT GAS CONTROL WHEN ATTACHING GAS SUPPLY PIPE TO PREVENT DAMAGING GAS LINE.ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUTWITH THE GLASS DOOR OPENED OR REMOVED. PURGING OF THE GAS SUPPLY LINE SHOULD BEPERFORMED BY A QUALIFIED SERVICE TECHNICIAN. ASSURE THAT A CONTINUOUS GAS FLOW IS ATTHE BURNER BEFORE CLOSING THE DOOR. ENSURE ADEQUATE VENTILATION. FOR GAS ANDELECTRICAL LOCATIONS, SEE “DIMENSION” SECTION.ALL GAS CONNECTIONS MUST BE CONTAINED WITHIN THE APPLIANCE WHEN COMPLETE.HIGH PRESSURE WILL DAMAGE VALVE. DISCONNECT GAS SUPPLY PIPING BEFORE TESTING GASLINE AT TEST PRESSURES ABOVE 1/2 PSIG.VALVE SETTINGS HAVE BEEN FACTORY SET, DO NOT CHANGE.4.6 GAS INSTALLATIONFor ease of accessibility, an optional remote wall switch or millivolt thermostat may be installed in a convenientlocation. Route a 2 strand, solid core millivolt wire from the valve to the wall switch or millivolt thermostat. Therecommended maximum lead length depends on wire size:WIRE SIZE MAX. LENGTH14 gauge 100 feet16 gauge 60 feet18 gauge 40 feetDisconnect the existing wires from terminals 1 and 3 (from theON/OFF switch) and replace with the leads from the wall switch / millivolt thermostat.50.1312! WARNINGDO NOT CONNECT EITHER THE WALL SWITCH, THERMOSTAT OR GAS VALVE DIRECTLY TO 110VOLT ELECTRICITY.4.7 OPTIONAL WALL SWITCH INSTALLATION4.6.14.6.24.6.34.6.44.6.54.6.6