ENW415-1468 / A / 09.30.1613! WARNINGNEVER INSTALL A SINGLE WALL SLIP SECTION OR SMOKE PIPE IN A CHASE STRUCTURE.THE HIGHER TEMPERATURE OF THIS SINGLE WALL PIPE MAY RADIATE SUFFICIENT HEAT TOCOMBUSTIBLE CHASE MATERIALS TO CAUSE FIRE.DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY SYSTEM SERVING ANOTHER APPLIANCE.TO AVOID DANGER OF FIRE, ALL INSTRUCTIONS MUST BE STRICTLY FOLLOWED, INCLUDINGTHE PROVISIONS OF AIR SPACE CLEARANCE BETWEEN CHIMNEY SYSTEM AND ENCLOSURE.TO PROTECT AGAINST THE EFFECTS OF CORROSION ON THOSE PARTS EXPOSED TO THEWEATHER, WE RECOMMEND THAT THE CHASE TOP BE PAINTED WITH A RUST RESISTANT PAINT.DO NOT FILL ANY FRAMED SPACE AROUND THE CHIMNEY WITH INSULATION OR ANY OTHERMATERIAL. INSULATION PLACED IN THIS AREA COULD CAUSE ADJACENT COMBUSTIBLES TOOVERHEAT.MAINTAIN A MINIMUM 2” (50.8mm) AIR CLEARANCE TO ALL PARTS OF THE CHIMNEY SYSTEM ATALL TIMES (EXCLUDING THE CHIMNEY CONNECTOR). FAILURE TO MAINTAIN THIS 2” (50.8mm) AIRCLEARANCE WILL CAUSE A STRUCTURE FIRE. NEVER FILL THIS SPACE WITH ANY TYPE OF MATERIAL.DETAILED INSTRUCTIONS FOR INSTALLATION OF THE CHASE TOP, STORM COLLAR ANDTERMINATION CAP ARE PACKAGED WITH THESE PARTS. MINIMUM CLEARANCE TOCOMBUSTIBLES WILL VARY DEPENDING ON THEIR DESIGN.DO NOT CUT RAFTERS OR CEILING JOISTS WITHOUT FIRST CONSULTING A BUILDING OFFICIALTO ENSURE STRUCTURAL INTEGRITY IS NOT COMPROMISED.FIRESTOP SPACERS MUST BE USED WHENEVER THE CHIMNEY PENETRATES A CEILING/FLOOR AREA.THE TOTAL HORIZONTAL VENT LENGTH SHOULD NOT EXCEED 40% OF THE CHIMNEY HEIGHTABOVE THE APPLIANCE. ALL HORIZONTAL SMOKE PIPE MUST SLOPE SLIGHTLY UPWARDS AMINIMUM OF 1/4” (21.2mm) PER FOOT (METER) AND ALL CONNECTIONS MUST BE TIGHT ANDSECURED BY THREE SHEET METAL SCREWS EQUALLY SPACED. AN UNINSULATED SMOKE PIPESHALL NOT PASS THROUGH AN ATTIC, ROOF SPACE, CLOSET, OR SIMILAR CONCEALED SPACE,OR THROUGH A FLOOR, CEILING, WALL OR PARTITION, OR ANY COMBUSTIBLE CONSTRUCTION.DO NOT USE ANY MAKESHIFT MATERIALS DURING INSTALLATION.63.8A4.1 CHIMNEYYour appliance may be connected to a factory built or masonry chimney. If you are using a factory builtchimney, it must comply with ULCS629 (Canada) or UL103 HT (USA) standards. It must therefore be a 6"(152.4mm) HT Type (2100°F) chimney. Use only specified components with no substitutions. It is extremelyimportant that it be installed according to the manufacturer's specifications. The manufacturer's installationinstructions and specified clearances should always be followed in accordance with local and national codes.In Canada the CSA B365 and the CSA C22.1 installation codes are to be followed. In the USA the ANSI NFPA70 and ANSI NFPA 211 installation codes are to be followed.Chimney and chimney connector must be in good condition and kept clean.