4.5 APPLIANCE VENT CONNECTION4.6 GAS INSTALLATION30.2Installation and servicing to be done by a qualified installer. Do not use open flame.A. Move the appliance into position and secure.B. If equipped with a flex connector the appliance is designed to accept a 1/2” gas supply. Without theconnector it is designed to accept a 3/8” gas supply. The appliance is equipped with a manual shut offvalve to turn off the gas supply to the appliance.C. Connect the gas supply in accordance to local codes. In the absence of local codes, install to thecurrent CAN/CSA-B149.1 Installation Code in Canada or to the current National Fuel Gas Code, ANSIZ223.1 / NFPA 54 in the United States.D. When flexing any gas line, support the gas valve so that the lines are not bent or kinked.E. Check for gas leaks by brushing on a soap and water solution.! WARNINGRISK OF FIRE, EXPLOSION OR ASPHYXIATION. ENSURE THERE ARE NO IGNITION SOURCES SUCHAS SPARKS OR OPEN FLAMES.SUPPORT GAS CONTROL WHEN ATTACHING GAS SUPPLY PIPE TO PREVENT DAMAGING GAS LINE.ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUTWITH THE GLASS DOOR OPENED OR REMOVED. PURGING OF THE GAS SUPPLY LINE SHOULD BEPERFORMED BY A QUALIFIED SERVICE TECHNICIAN. ASSURE THAT A CONTINUOUS GAS FLOW IS ATTHE BURNER BEFORE CLOSING THE DOOR. ENSURE ADEQUATE VENTILATION. FOR GAS ANDELECTRICAL LOCATIONS, SEE “DIMENSION” SECTION.HIGH PRESSURE WILL DAMAGE VALVE. DISCONNECT GAS SUPPLY PIPING BEFORE TESTING GASLINE AT TEST PRESSURES ABOVE 1/2 PSIG.VALVE SETTINGS HAVE BEEN FACTORY SET, DO NOT CHANGE.28.5AA. Attach the adjustable pipe to the last section of rigid pipe. Securewith screws and seal.B. Install the inner flex pipe to the appliance. Secure with 3 screwsand flat washers. Seal the joint and screw holes using the hightemperature sealant W573-0007 (not supplied).C. Run a bead of high temperature sealant (not supplied) around theinside of the air intake collar. Pull the adjustable pipe a minimum 2”(50.8mm) into the air intake collar.NOTE: Ensure that the sealant is not visible on the exterior pipes onceinstallation is completed. An optional decorative black band is availablefor this use. In the event that the venting must be disassembled, caremust be taken to reseal the venting.#8 X 1/2”SELFDRILLINGSCREWSHIGH TEMPERATURESEALANT2” (50.8mm)OVERLAPW415-0547 / J / 07.16.1322EN