19W415-0379 / C / 03.12.10INSTALLATION TO BE DONE BY A QUALIFIED INSTALLER and mustbe electrically connected and grounded in accordance with local codes.In the absence of local codes, use the current ANSI / NFPA 70 NationalElectrical Code.If the appliance was not previously equipped with a blower:Route a grounded 2-wire, 60hz power cable to the receptacle /junction box. At this point, it must be strain relieved and insulated.The three slots on the blower mounting bracket allow ease ofadjustment when attaching the blower. For a quiet running blower, do not allow theassembly to sit on the firebox base. Slide the vibration reducing pad (A) into theclip (C) and up against the threaded stud (B) at the other end. The blower mustbe able to be positioned entirely onto the pad.To ease installation of the blower, remove the hinge screen and valve control door(lower louvres) from the base of the appliance.Tilt the blower onto its side. Slide it past the controls and into the clip (C).Secure to the threaded stud using the lock washer and wing nut provided.Ensure that the blower does not touch the appliance base or the firebox.Attach the connectors from the black and whitewires to the thermal switch and secure thethermal switch bracket to the bottom left of theunit using the screws provided. Ensure that thethermal switch touches the firebox wall.Attach the connectors from the black and redwires to the blower.blackwhiteredVARIABLESPEEDSWITCHBLOWERTHERMALSWITCHSLOTSELONGATEDABC6.0 OPTIONAL BLOWER INSTALLATION! WARNINGRISK OF FIRE AND ELECTRICAL SHOCK.TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THIS APPLIANCE.USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITHTHIS APPLIANCE. USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, GASCOMPONENTS, VENTING COMPONENTS, ETC.) COULD RESULT IN A SAFETY HAZARD AND WILLVOID THE WARRANTY AND CERTIFICATION.ENSURE THAT THE FAN’S POWER CORD IS NOT IN CONTACT WITH ANY SURFACE OF THEAPPLIANCE TO PREVENT ELECTRICAL SHOCK OR FIRE DAMAGE. DO NOT RUN THE POWERCORD BENEATH THE APPLIANCE.THE WIRE HARNESS PROVIDED IN THE BLOWER KIT IS A UNIVERSAL HARNESS. WHENINSTALLED, ENSURE THAT ANY EXCESS WIRE IS CONTAINED, PREVENTING IT FROM MAKINGCONTACT WITH MOVING OR HOT OBJECTS.51.5