W415-1259 / 10.22.138EN3.0 VENTING7.2CTHIS APPLIANCE USES A 5” (127mm) EXHAUST / 8” (203.2mm) AIR INTAKE VENT PIPE SYSTEM.Refer to the section applicable to your installation.For safe and proper operation of the appliance follow the venting instruction exactly. Deviation from theminimum vertical vent length can create difficulty in burner start-up and/or carboning. Under extreme ventconfigurations, allow several minutes (5-15) for the flame to stabilize after ignition. Provide a means forvisually checking the vent connection to the appliance after the appliance is installed. Use a firestop, vent pipeshield or attic insulation shield when penetrating interior walls, floor or ceiling.NOTE: If for any reason the vent air intake system is disassembled; reinstall per the instructionsprovided for the initial installation.NOTE: This appliance must be installed with a continuous connection of exhaust and air intake ventpipes. Utilizing alternate constructions such as a chimney as part of the vent system is not permitted.! WARNINGRISK OF FIRE, MAINTAIN SPECIFIED AIR SPACE CLEARANCES TO VENT PIPE AND APPLIANCE.IF VENTING IS INCLUDED WITH SPACERS THE VENT SYSTEM MUST BE SUPPORTED EVERY 3FT(0.9m) FOR BOTH VERTICAL AND HORIZONTAL RUNS. USE SUPPORTS OR EQUIVALENTNON-COMBUSTIBLE STRAPPING TO MAINTAIN THE REQUIRED CLEARANCE FROMCOMBUSTIBLES. USE WOLF STEEL LTD. SUPPORT RING ASSEMBLY W010-0370 OR EQUIVALENTNON-COMBUSTIBLE STRAPPING TO MAINTAIN THE MINIMUM CLEARANCE TO COMBUSTIBLESFOR BOTH VERTICAL AND HORIZONTAL RUNS. SPACERS ARE ATTACHED TO THE INNER PIPE ATPREDETERMINED INTERVALS TO MAINTAIN AN EVEN AIR GAP TO THE OUTER PIPE. THIS GAP ISREQUIRED FOR SAFE OPERATION. A SPACER IS REQUIRED AT THE START, MIDDLE AND END OFEACH ELBOW TO ENSURE THIS GAP IS MAINTAINED. THESE SPACERS MUST NOT BE REMOVED.3.1 VENTING LENGTHS AND COMPONENTSUse only Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent or Metal-Fabventing components. Minimum and maximum vent lengths, for both horizontal and vertical installations,and air terminal locations for either system are set out in this manual and must be adhered to. For SimpsonDura-Vent, Selkirk Direct Temp, American Metal Amerivent and Metal-Fab follow the installation procedureprovided with the venting components.A starter adaptor must be used with the following vent systems and may be purchased from thecorresponding supplier:For Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent and Metal-Fab follow the installationprocedure found on the website for your venting supplier.For vent systems that provide seals on the inner exhaust flue, only the outer air intake joints must be sealed using ared high temperature silicone (RTV). This same sealant may be used on both the inner exhaust and outer intake ventpipe joints of all other approved vent systems except for the exhaust vent pipe connection to the appliance flue collarwhich must be sealed using the black high temperature sealant Mill Pac.When using Wolf Steel venting components, use only approved Wolf Steel rigid / flexible components with the followingtermination kits: wall terminal kit GD422-1, GD422R-1, or 1/12 to 7/12 pitch roof terminal kit GD410, 8/12 to 12/12 roofterminal kit GD411, flat roof terminal kit GD412 or periscope kit GD401 (for wall penetration below grade). With flexibleventing, in conjunction with the various terminations, use either the 5 foot (1.5m) vent kit GD420 or the 10 foot (3.1m)vent kit GD430.PART 5”/8” SUPPLIER WEBSITEDuravent W175-0170 Wolf Steel www.duravent.comAmerivent 5DSC-N2 American Metal www.americanmetalproducts.comDirect Temp 5DT-AA Selkirk www.selkirkcorp.comSuperSeal 5DDA Metal-Fab www.mtlfab.com