W415-0910 / A / 09.16.101INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.INSTALLATION ANDOPERATING INSTRUCTIONSWolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 4Y8 Canada /103 Miller Drive, Crittenden, Kentucky, USA, 41030Phone (705)721-1212 • Fax (705)722-6031 • www.napoleonfireplaces.com • ask@napoleonproducts.comSAFETY INFORMATION! WARNINGIf the information in these instructions are not followedexactly, a fire or explosion may result causing propertydamage, personal injury or death.Please read entire manual before you install and use yourheater.- This heater can be very hot when burning.- Combustible materials such as fi rewood, wet clothing, etc.placed too close can catch fi re.- Children and pets must be kept from touching the heater whenit is hot.- The chimney must be sound and free of cracks. Beforeinstalling this unit, contact the local building or fi re or otherauthority having jurisdiction and follow their guidelines.- Operate only with the doors tightly closed.- Do not use an elevated grate or otherwise raise the fi re.- This heater is designed to burn natural wood only. Highereffi ciencies and lower emissions generally result whenburning air dried seasoned hardwoods, as compared tosoftwoods or to green or freshly cut hardwoods.- Do not start a fire with chemicals or fl uids such as gasoline,engine oil, etc.- Do not burn treated wood, coal, charcoal, coloured paper,cardboard, solvents or garbage.- Do not let the heater become hot enough for any part to glowred.W385-0413HMF150LISTED SOLID FUEL FIRED CENTRAL FURNACETESTED TO:CAN-CSA B366-1-M91 / UL391 4th Ed 2006 (JULY 2008) / UL 727 / CSA B140.4 / CSA B212MODEL: HMF150REPORT NO.: _ 415-S-09-2_CAUTION: HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY.CONTACT MAY CAUSE SKIN BURNS. SEE NAMEPLATE AND INSTRUCTIONS.TECHNICAL DATABLOWER / VENTILATEUR1/3 HPELECTRICAL RATING /120V, 10.3 AMPS,ALIMENTATION ELECTRIQUE60HzEXTERNAL STATIC PRESSURE / 0.2” W.C.PRESSION STATIQUE EXT.0.2” C.E.DRAFT PRESSURE/WOOD FLUE:MIN. 0.4” W.COIL FLUE:0.2”W.C.OIL FURNACE - OIL FIRING RATE: 0.66 GAL US- OIL PRESSURE: 120 PSI- NOZZLE:0.65 - 60°AINSTALLATION - USE ONLY IN ACCORDANCE WITH WOLF STEEL LTD’S INSTRUCTIONS. CONTACT LOCAL BUILDING, FIRE OFFICIALS AND OTHER AGENCIES HAVING LOCAJURISDICTION ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA.CHIMNEY TYPE: FOR “WOOD ONLY” FURNACE CONFIGURATION MINIMUM 6” (152mm) DIAMETER LISTED (UL 103HT) RESIDENTIAL CHIMNEY. FOR “WOOD/OILCOMBINATION” FURNACE RECOMMENDED MINIMUM 7”(178mm) DIAMETER LISTED (UL 103HT) RESIDENTIAL CHIMNEY.DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE UNLESS USING IN A “ADD ON” CONFIGURATION WITH A PRE EXISITNG OILFURNACE - SEE MANUAL UNDER PLENUM AND INSTALLATION.CHIMNEY CONNECTOR: 6” (152mm) DIAMETER MINIMUM 24 GAUGE STEEL MINIMUM CLEARANCE FROM HORIZONTAL CONNECTOR AND CEILING 18” (455mm).SPECIAL METHODS ARE REQUIRED WHEN PASSING A CHIMNEY THROUGH A WALL OR CEILING. SEE INSTRUCTIONS AND BUILDING CODES.DO NOT OBSTRUCT SPACE UNDER FURNACE. UNIT CAN BE INSTALLED ON COMBUSTIBLE SURFACE (WOOD SUBSTRATE ONLY – CARPET AND OTHER FLOORCOVERINGS TO BE REMOVED) PROVIDING EMBER STOP SHIELD (SEE MANUAL) INSTALLED BETWEEN FURNACE AND FLOOR AND MINIMUM 1 ¼” AIR GAPMAINTAINED BETWEEN FURNACE AND FLOOR.FUEL: FOR USE WITH SOLID WOOD FUEL ONLY. DO NOT USE GRATE OR ELEVATE FIRE. BUILD WOOD FIRE DIRECTLY ON HEARTH.AUTHORIZED MODULES FOR CONNECTION TO HMF150 FURNACE:BLOWER BOX MODULE - HMFK-BMP33ELECTRIC FURNACE MODULE - HMFK-EF20OIL FURNACE MODULES - HMFK-OFRF40, HMFK-OFAFGDHW PREHEAT MODULE - HMFK-DHW“ADD ON” FURNACE MODULE - HMFK-ADDONTHESE ARE THE ONLY AUTHORIZED COMPONENTS THAT MAY BE ATTACHED TO THE HMF150 FURNACE ASIDE FROM CONNECTION TO FORCED AIR SYSTEMRETURN AND SUPPLY PLENUMS. MODULES MUST BE INSTALLED TO MANUFACTURERS INSTRUCTIONS POSTED IN THE INSTALLATION/OWNERS MANUALACCOMPANYING HMF150 AND INSTRUCTION ADDENDUMS INCLUDED WITH EACH MODULE.THE HMF150 FURNACE IS CERTIFIED FOR SERIES CONNECTION TO THE SUPPLY PLENUM OUTLET ONLY OF A GAS FIRED, OIL FIRED, OR ELECTRIC FURNACE WHENUSED AS AN WOOD FURNACE “ADD-ON”.DO NOT CONNECT THIS FURNACE TO A CHIMNEY SERVICE A GAS FURNACE.DO NOT CONNECT DUCTWORK SO THAT REVERSE FLOW IS POSSIBLE.DO NOT RELOCATE OR BYPASS ANY OF THE SAFETY CONTROLS IN THE ORIGINAL FURNACE INSTALLATION (”ADD ON” CONFIGURATION).CAUTION: THIS APPLIANCE MUST BE INSTALLED BY A QUALIFIED INSTALLER. USE OF UNAUTHORIZED COMPONENTS OR FAILURE TO COMPLY WITHINSTALLATION INSTRUCTIONS WILL RESULT IN VOIDED WARRANTY.WARNING: RISK OF SMOKE SPILLAGE. OPERATE ONLY WITH FIRING AND ASH REMOVAL DOOR TIGHTLY CLOSED. DO NOT OVERFIRE.IF HEATER OR CHIMNEY CONNECTORS GLOW, YOU ARE OVERFIRING – IMMEDIATELY TURN OFF THERMOSTAT AND ENSURE PRIMARY SHUTTER FIRING AND ASHREMOVAL DOOR ARE CLOSED.SEE MANUAL FOR OPERATION OF WOOD FURNACE IF ELECTRICAL POWER HAS BEEN INTERRUPTED.THE HEAT EXCHANGER, FLUE PIPE AND CHIMNEY MUST BE INSPECTED FREQUENTLY AND CLEANED REGULARLY TO REMOVE ACCUMULATED CREOSOTE ANDASH. UNDER CERTAIN CONDITIONS OF USE, CREOSOTE BUILDUP MAY OCCUR RAPIDLY. ENSURE THAT THE HEAT EXCHANGER, FLUE PIPE AND CHIMNEY ARECLEANED AT END OF BURNING SEASON, THIS HELPS TO MINIMIZE CORROSION IN THE SUMMER MONTHS. THE APPLIANCE, FLUE PIPE AND CHIMNEY MUST BEMAINTAINED IN GOOD CONDITION. UNSAFE TO FIRE WITH WOOD ABOVE TOP OF REFRACTORY BRICK INSIDE COMBUSTIBLE CHAMBER.REPLACE ALL CRACKED OR BROKEN FIRE BRICK AND TOP BAFFLES.LOAD FUEL CAREFULLY OR DAMAGE MAY RESULT.DO NOT ATTEMPT TO LIGHT A FIRE IF THERE IS AN OIL VAPOUR PRESENT.DO NOT USE CHEMICALS OR FLUIDS TO START THE FIRE.DO NOT BURN GARBAGE, GASOLINE, NAPHTA, ENGINE OIL OR OTHER INAPPROPRIATE MATERIALS.DO NOT STORE FUEL OR COMBUSTIBLE MATERIAL WITHIN INSTALLATION CLEARANCES OF THE APPLIANCE.DO NOT USE THIS FURNACE WITHOUT DUCTS – SEE MANUAL FOR ALLOWABLE CONFIGURATION.CAUTION: USE SUPPLY WIRES SUITABLE FOR 167°F/75°C. SEE INSTRUCTION MANUAL FOR ELECTRICAL DIAGRAM.CAUTION: REPLACE GLASS ONLY WITH CERAMIC GLASS.DANGER: RISK OF ELECTRICAL SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT - DISCONNECT POWER FROM BOTH FURNACES IN A “ADD ON”CONFIGURATION.MAY BE ADDED ONTO A FURNACE HAVING A RATING AS SHOWN ON THE ORIGINAL NAME PLATE BETWEEN: 15 KW MINIMUM AND 20 KW MAXIMUM FOR ELECTRIC FURNACE 0.4 MINIMUM AND 0.65 MAXIMUM USGPH FOR OIL FURNACE 60,000 MINIMUM AND 80,000 MAXIMUM BTU/H FOR GAS FURNACECAUTION: MAINTAIN COMBUSTION AIR SUPPLY TO BOTH FURNACES. AIR STARVATION IS DANGEROUS (SEE MANUAL UNDER “OUTSIDE COMBUSTION AIR”).FOR “ADD ON” INSTALLATION REFER TO MANUFACTURES INSTRUCTIONS FROM ORIGINAL FURNACE FOR INFORMATION ON MINIMUM DUCT SIZING, ALLOWABLEDUCT OPENINGS IN FURNACE CASING AND ELECTRIC DIAGRAMS AND INFORMATION.OPERATE ORIGINAL FURNACE (ELECTRIC, OIL, GAS) OF A “ADD ON” CONFIGURATION PERIODICALLY TO ENSURE IT WILL OPERATE SATISFACTORILY WHEN NEEDED.6 ft6”1”1.25”MODEL NO.SERIAL NO.MADE IN CANADA WITH DOMESTIC AND IMPORTED PARTS BY:WOLF STEEL LTD. 24 NAPOLEON ROAD, BARRIE, ON, L4M 4Y8 CANADA18”26” 26”17”14” AND “S”1.25”48”“S”14”NOTE:“S” = MINIMUM 24” SERVICE CLEARANCE REQUIREDREFER TO SECTION 6.0 OF THE INSTALLATION AND OPERATING INSTRUCTION MANUAL.W385-0413HMF150LISTED SOLID FUEL FIRED CENTRAL FURNACETESTED TO:CAN-CSA B366-1-M91 / UL391 4th Ed 2006 (JULY 2008) / UL 727 / CSA B140.4 / CSA B212MODEL: HMF150REPORT NO.: _ 415-S-09-2_CAUTION: HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY.CONTACT MAY CAUSE SKIN BURNS. SEE NAMEPLATE AND INSTRUCTIONS.TECHNICAL DATABLOWER / VENTILATEUR1/3 HPELECTRICAL RATING /120V, 10.3 AMPS,ALIMENTATION ELECTRIQUE60HzEXTERNAL STATIC PRESSURE / 0.2” W.C.PRESSION STATIQUE EXT.0.2” C.E.DRAFT PRESSURE/WOOD FLUE:MIN. 0.4” W.COIL FLUE:0.2”W.C.OIL FURNACE - OIL FIRING RATE: 0.66 GAL US- OIL PRESSURE: 120 PSI- NOZZLE:0.65 - 60°AINSTALLATION - USE ONLY IN ACCORDANCE WITH WOLF STEEL LTD’S INSTRUCTIONS. CONTACT LOCAL BUILDING, FIRE OFFICIALS AND OTHER AGENCIES HAVING LOCAJURISDICTION ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA.CHIMNEY TYPE: FOR “WOOD ONLY” FURNACE CONFIGURATION MINIMUM 6” (152mm) DIAMETER LISTED (UL 103HT) RESIDENTIAL CHIMNEY. FOR “WOOD/OILCOMBINATION” FURNACE RECOMMENDED MINIMUM 7”(178mm) DIAMETER LISTED (UL 103HT) RESIDENTIAL CHIMNEY.DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE UNLESS USING IN A “ADD ON” CONFIGURATION WITH A PRE EXISITNG OILFURNACE - SEE MANUAL UNDER PLENUM AND INSTALLATION.CHIMNEY CONNECTOR: 6” (152mm) DIAMETER MINIMUM 24 GAUGE STEEL MINIMUM CLEARANCE FROM HORIZONTAL CONNECTOR AND CEILING 18” (455mm).SPECIAL METHODS ARE REQUIRED WHEN PASSING A CHIMNEY THROUGH A WALL OR CEILING. SEE INSTRUCTIONS AND BUILDING CODES.DO NOT OBSTRUCT SPACE UNDER FURNACE. UNIT CAN BE INSTALLED ON COMBUSTIBLE SURFACE (WOOD SUBSTRATE ONLY – CARPET AND OTHER FLOORCOVERINGS TO BE REMOVED) PROVIDING EMBER STOP SHIELD (SEE MANUAL) INSTALLED BETWEEN FURNACE AND FLOOR AND MINIMUM 1 ¼” AIR GAPMAINTAINED BETWEEN FURNACE AND FLOOR.FUEL: FOR USE WITH SOLID WOOD FUEL ONLY. DO NOT USE GRATE OR ELEVATE FIRE. BUILD WOOD FIRE DIRECTLY ON HEARTH.AUTHORIZED MODULES FOR CONNECTION TO HMF150 FURNACE:BLOWER BOX MODULE - HMFK-BMP33ELECTRIC FURNACE MODULE - HMFK-EF20OIL FURNACE MODULES - HMFK-OFRF40, HMFK-OFAFGDHW PREHEAT MODULE - HMFK-DHW“ADD ON” FURNACE MODULE - HMFK-ADDONTHESE ARE THE ONLY AUTHORIZED COMPONENTS THAT MAY BE ATTACHED TO THE HMF150 FURNACE ASIDE FROM CONNECTION TO FORCED AIR SYSTEMRETURN AND SUPPLY PLENUMS. MODULES MUST BE INSTALLED TO MANUFACTURERS INSTRUCTIONS POSTED IN THE INSTALLATION/OWNERS MANUALACCOMPANYING HMF150 AND INSTRUCTION ADDENDUMS INCLUDED WITH EACH MODULE.THE HMF150 FURNACE IS CERTIFIED FOR SERIES CONNECTION TO THE SUPPLY PLENUM OUTLET ONLY OF A GAS FIRED, OIL FIRED, OR ELECTRIC FURNACE WHENUSED AS AN WOOD FURNACE “ADD-ON”.DO NOT CONNECT THIS FURNACE TO A CHIMNEY SERVICE A GAS FURNACE.DO NOT CONNECT DUCTWORK SO THAT REVERSE FLOW IS POSSIBLE.DO NOT RELOCATE OR BYPASS ANY OF THE SAFETY CONTROLS IN THE ORIGINAL FURNACE INSTALLATION (”ADD ON” CONFIGURATION).CAUTION: THIS APPLIANCE MUST BE INSTALLED BY A QUALIFIED INSTALLER. USE OF UNAUTHORIZED COMPONENTS OR FAILURE TO COMPLY WITHINSTALLATION INSTRUCTIONS WILL RESULT IN VOIDED WARRANTY.WARNING: RISK OF SMOKE SPILLAGE. OPERATE ONLY WITH FIRING AND ASH REMOVAL DOOR TIGHTLY CLOSED. DO NOT OVERFIRE.IF HEATER OR CHIMNEY CONNECTORS GLOW, YOU ARE OVERFIRING – IMMEDIATELY TURN OFF THERMOSTAT AND ENSURE PRIMARY SHUTTER FIRING AND ASHREMOVAL DOOR ARE CLOSED.SEE MANUAL FOR OPERATION OF WOOD FURNACE IF ELECTRICAL POWER HAS BEEN INTERRUPTED.THE HEAT EXCHANGER, FLUE PIPE AND CHIMNEY MUST BE INSPECTED FREQUENTLY AND CLEANED REGULARLY TO REMOVE ACCUMULATED CREOSOTE ANDASH. UNDER CERTAIN CONDITIONS OF USE, CREOSOTE BUILDUP MAY OCCUR RAPIDLY. ENSURE THAT THE HEAT EXCHANGER, FLUE PIPE AND CHIMNEY ARECLEANED AT END OF BURNING SEASON, THIS HELPS TO MINIMIZE CORROSION IN THE SUMMER MONTHS. THE APPLIANCE, FLUE PIPE AND CHIMNEY MUST BEMAINTAINED IN GOOD CONDITION. UNSAFE TO FIRE WITH WOOD ABOVE TOP OF REFRACTORY BRICK INSIDE COMBUSTIBLE CHAMBER.REPLACE ALL CRACKED OR BROKEN FIRE BRICK AND TOP BAFFLES.LOAD FUEL CAREFULLY OR DAMAGE MAY RESULT.DO NOT ATTEMPT TO LIGHT A FIRE IF THERE IS AN OIL VAPOUR PRESENT.DO NOT USE CHEMICALS OR FLUIDS TO START THE FIRE.DO NOT BURN GARBAGE, GASOLINE, NAPHTA, ENGINE OIL OR OTHER INAPPROPRIATE MATERIALS.DO NOT STORE FUEL OR COMBUSTIBLE MATERIAL WITHIN INSTALLATION CLEARANCES OF THE APPLIANCE.DO NOT USE THIS FURNACE WITHOUT DUCTS – SEE MANUAL FOR ALLOWABLE CONFIGURATION.CAUTION: USE SUPPLY WIRES SUITABLE FOR 167°F/75°C. SEE INSTRUCTION MANUAL FOR ELECTRICAL DIAGRAM.CAUTION: REPLACE GLASS ONLY WITH CERAMIC GLASS.DANGER: RISK OF ELECTRICAL SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT - DISCONNECT POWER FROM BOTH FURNACES IN A “ADD ON”CONFIGURATION.MAY BE ADDED ONTO A FURNACE HAVING A RATING AS SHOWN ON THE ORIGINAL NAME PLATE BETWEEN: 15 KW MINIMUM AND 20 KW MAXIMUM FOR ELECTRIC FURNACE 0.4 MINIMUM AND 0.65 MAXIMUM USGPH FOR OIL FURNACE 60,000 MINIMUM AND 80,000 MAXIMUM BTU/H FOR GAS FURNACECAUTION: MAINTAIN COMBUSTION AIR SUPPLY TO BOTH FURNACES. AIR STARVATION IS DANGEROUS (SEE MANUAL UNDER “OUTSIDE COMBUSTION AIR”).FOR “ADD ON” INSTALLATION REFER TO MANUFACTURES INSTRUCTIONS FROM ORIGINAL FURNACE FOR INFORMATION ON MINIMUM DUCT SIZING, ALLOWABLEDUCT OPENINGS IN FURNACE CASING AND ELECTRIC DIAGRAMS AND INFORMATION.OPERATE ORIGINAL FURNACE (ELECTRIC, OIL, GAS) OF A “ADD ON” CONFIGURATION PERIODICALLY TO ENSURE IT WILL OPERATE SATISFACTORILY WHEN NEEDED.6 ft6”1”1.25”MODEL NO.SERIAL NO.MADE IN CANADA WITH DOMESTIC AND IMPORTED PARTS BY:WOLF STEEL LTD. 24 NAPOLEON ROAD, BARRIE, ON, L4M 4Y8 CANADA18”26” 26”17”14” AND “S”1.25”48”“S”14”NOTE:“S” = MINIMUM 24” SERVICE CLEARANCE REQUIREDREFER TO SECTION 6.0 OF THE INSTALLATION AND OPERATING INSTRUCTION MANUAL.$10.00HYBRID 150HMF150MULTI-FUEL FURNACECERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: UL 391, UL 727, CSA B366.1-M91, B140.4-04, CSA B212-00.