W415-1198 / 05.24.1319ENA. Frequent beeping for 3 seconds when the appliance turns on indicates low battery on the remotereceiver. The battery pack is located on the bottom right side of the appliance, refer to "INSTALLATIONOVERVIEW" for location.B. Low battery indicator is in the top right corner of the remote, we also recommend replacing thebatteries every two years.NOTE: When low battery occurs the appliance will shut down. The appliance will shut off if no changehas occurred to the flame height or the appliance has not turned on for a period of 5 days.IR3-1NG 1/16” (1.6mm)LP 3/8" (9.5mm)Adjust the pilot screw to provide properly sized flame. Turn in aclockwise direction to reduce the gas flow.Check Pressure Readings:Inlet pressure can be checked by turning screw (A) counter-clockwise2 or 3 turns and then placing pressure gauge tubing over the test point.Gauge should read as described on the chart below. Check thatmain burner is operating on “HI”.Outlet pressure can be checked the same as above usingscrew (B). Gauge should read as described on the chartbelow. Check that main burner is operating on “HI”.AFTER TAKING PRESSURE READINGS, BE SURE TOTURN SCREWS CLOCKWISE FIRMLY TO RESEAL. DONOT OVERTORQUE.Leak test with a soap and water solution.Prior to pilot adjustment, ensure that the pilotassembly has not been painted. If overspray orpainting of the pilot assembly has occurred removethe paint from the pilot assembly, or replace. Fineemery cloth or sandpaper can be used to remove the paint from the pilot hood, electrode and flame sensor.39.8AABPILOTSCREWFLAME MUST ENVELOPUPPER 3/8” (9.5mm) TO 1/2”(12.7mm) OF THERMOCOUPLEPILOTBURNERELECTRODETHERMOCOUPLE3/8” - 1/2”(9.5mm - 12.7mm)MANUALKNOBPressureInletOutletNatural Gas(inches)Natural Gas(millibars)Propane(inches)Propane(millibars)7"(MIN. 4.5")3.5"13"(MIN. 11")10"17.4mb(MIN. 11.2mb)8.7mb32.4mb(MIN. 27.4mb)24.9mbThis appliance has an air shutter that has been factory set open accordingto the chart below:Regardless of venturi orientation, closing the air shutter will cause a moreyellow flame, but can lead to carboning. Opening the air shutter will cause amore blue flame, but can cause flame lifting from the burner ports. Theflame may not appear yellow immediately; allow 15 to 30 minutes for thefinal flame colour to be established.AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIEDINSTALLER!AIRSHUTTEROPENINGVENTURIBURNERORIFICE49.16.2.10 LOW BATTERY7.0 ADJUSTMENTS7.1 PILOT BURNER ADJUSTMENT7.2 VENTURI ADJUSTMENT