ENW415-1867 / B / 02.07.19 115.0 remote control layout5.2 split flow (GDIX4 only)Low battery alarmKey LockRoomTemperatureLightFlame ONBlowerTransmissionCPI modeSplit FlowThe split flow function controls the ability to turn ON /OFF a second burner.1. Use the mode key to guide you to the splitfl ow function.2. Pressing the up arrow key will activate thesecond burner.3. Pressing the down arrow key will deactivatethe second burner. A single “beep” willconfi rm the reception of the command.note:This is no way to modulate the flame heights separately.76 °FOFF 76 °FON5.3 initializing the transmitter / battery holder for the first timeA. Install the 4 AA batteries into the Profl ame 2 battery holder, note the polarity of the batteries and insert asindicated on the cover (+/-).B. Ensure the 3 position slider switch is switched to the “REMOTE” position (middle position).C. Press the reset/programming button, use a small object such as a paper clip in order to reach the buttonmarked PRG, as shown in the illustration below.D. The battery holder will beep 3 times to indicate that it’s ready to synchronize with the transmitter.E. Install the 3 AAA batteries into the transmitter, as shown in the photograph below, then press the ONbutton, The battery holder will beep 4 times to indicate that the transmitter’s command is accepted.note:The initializing process must be completed within 10 seconds of pressing the reset/program button (PRG).(4) AA BatteriesTRANSMITTERRESET/PROGRAMBUTTON (PRG)BATTERY HOLDERSLIDER SWITCH5.1 general transmitter layout