© National Instruments | 1-31NI cDAQ-9181/9184/9188/9191 User ManualCables and AccessoriesTable 1-8 contains information about cables and accessories available for the cDAQ chassis. Fora complete list of cDAQ chassis accessories and ordering information, refer to the pricingsection of the cDAQ-9181/9184/9188/9191 product page at ni.com.Removing Modules from the cDAQ ChassisComplete the following steps to remove a C Series module from the chassis.1. Make sure that no I/O-side power is connected to the module. If the system is in anonhazardous location, the chassis power can be on when you remove modules.2. Squeeze the latches on both sides of the module and pull the module out of the chassis.Table 1-8. cDAQ Chassis Cables and AccessoriesAccessory Part Number cDAQ ChassisNI 9901 desktop mounting kit 779473-01 cDAQ-9184/9188NI 9903 panel mount kit 781722-01 cDAQ-9181/9191NI 9904 panel mount kit 779097-01 cDAQ-9184NI 9905 panel mount kit 779558-01 cDAQ-9188NI 9912 DIN rail mounting kit 779019-01 cDAQ-9184NI 9913 DIN rail mounting kit 781740-01 cDAQ-9181/9191NI 9915 DIN rail mounting kit 779018-01 cDAQ-9188NI 9925 IP enclosure 781723-01 cDAQ-9181/91912-pos screw terminal kit for powersupply connection, qty 4780702-01 AllCAT-5E Ethernet cable, shielded,(2 m, 5 m, and 10 m lengths)151733-02/05/10 All