uPASS Access© Nedap AVI Page 17 of 195.3.3 EXTRA OUTPUTOptionally enable wiegand or magstripe output for tags that are not programmed by Nedap in a wiegand,magstripe or nedap-xs format. This feature is introduced in firmware version 2.13 or newer.'Protocol':Disabled Do not use the additional output feature.Wiegand Enable additional wiegand output.Magstripe Enable additional magstripe output.'Data source':EPC number Output the EPC number using the selected protocol.Custom read data Output the custom data read using the selected protocol.See for more information about how to setup custom read data chapter 5.2.1.'Alignment':Full Use the complete EPC number (or all custom read data).Left Truncate data. Keep left.Right Truncate data. Keep right.'Data length': Data length in bits for wiegand (or in digits for magstripe).'Offset': Data offset in bits for wiegand (or in digits for magstripe).'Add constant': Enable to add a constant to the output before or after the data read from the tag.Example 1: Output a wiegand 26-bit message withfacility code 10:Figure 13: Additional output example 1Example 2: Output the 13 rightmost digits from theEPC number using the magstripe interface:Figure 14: Additional output example 2