INSTRUCTION MANUALDocument ID: 73-H001. Copyright © Nilar AB. All rights reserved. Page 11 (32)Figure 22: Design Fan connector, type Molex 51103-04004.3.9 Power In (⑧, red ●)The 24VDC power supply that runs the IMU isconnected to the connection marked ‘Power In’.Connector: PT 1,5/4-PVH-5,0 (e.g. Phoenix contact1934887 or 1805533)Nominal voltage: 24VDC (20VDC - 28VDC allowed)Power consumption: 1,5W + fan power x 1.2 (if fan isused)Figure 23: Power In connection, schematicFigure 24: Design Power in connector, type Phoenix 1934887. With front-/outside visible (screws on top)For a more detailed description of the IMU, please refer to the EDSdescription (doc. Id: SPN-170063-88-H001)