Installation 3-3Part 1032059B 2003 Nordson Corporation Manual 41-DURABLUE-MA-02Installation RequirementsBefore installing the melter, ensure that the desired installation locationprovides the required clearances, environmental conditions, and utilities.ClearancesFigure 3-1 illustrates the minimum clearances that are required between themelter and surrounding objects. Table 3-1 describes each clearance.Figure 3-1 Minimum installation clearancesTable 3-1 Minimum Installation ClearancesItem DescriptionRequired ClearanceItem Description D10LD16L D4LA Width of melter at the outside of the mountingbrackets.441 mm(17.36 in.)334 mm(13.14 in.)B Clearance required between the melter andthe nearest object in order to remove thefilter.203 mm(8.00 in.)203 mm(8.00 in.)CClearance required between the front end ofthe melter (control panel) and the nearestobject in order to fully open the electricalenclosure door330 mm(13.00 in.)279 mm(11.00 in.)D Minimum horizontal space required for themelter when both the electrical enclosuredoor and tank lid are fully opened.1126 mm(44.34 in.)908 mm(35.73 in.)E Minimum vertical space required for themelter when the tank lid is at its highest point.861 mm(33.90 in.)623 mm(24.54 in.)