Troubleshooting 6-7Part 1124631_01E 2015 Nordson CorporationResolving Alerts and FaultsWhen a fault or alert condition occurs, the screen background color flashesred or yellow until the message has been acknowledged.Tap the button (item 6 in Figure 6-2:) on the Message Log screen toacknowledge the message. After the alert or fault has been acknowledged,the background stops flashing. Depending on the type of fault or alert,holding the acknowledge button may also clear the fault or alert condition,sending it to the inactive section of the log.If the fault or alert condition continues after the message has beenacknowledged, further steps must be taken to resolve the problem. Use thetroubleshooting tips in the message log as a guide.Shortcut ButtonsSee item 7 in Figure 6-2: for the location of the shortcut button. Depending onthe type of events that occur, one of the following button appears onMessage Log screen:Button EventPurgeApplicatorMachine SettingsSelf TestComponentsArchiveThese buttons provide menu shortcuts that are related to the message. Themessages provide corrective actions.