Overview2-4Part 1124631_01 E 2015 Nordson CorporationComparison TableThe following table compares a pattern controller with or without the add-onfeatures.Add-on Options WITH Add-on Features(Software Licences Obtained)WITHOUT Add-on Features(Software Licences NOT Obtained)Encoder Time, quadrature and single encodertypes are available.Time is the only source available.Power to the encoder is enabled. Power to the encoder is not enabled.Current and encoder pulses aredetected.Encoder is not detected.Line speed is computed and scaledbased on the encoder type and scalevalue.Line speed is constant.(Unscaled, the line speed is 1 ms [1 mmat 60 m/min]).Encoder screen available. Encoder screen is not available.Enable auto type and direction detectionduring commissioning.No auto type and direction detection.Encoder icon is displayed and can betouched.Encoder icon is not visible.Encoder related alerts and faultsenabled.No encoder related alerts and faults.Pressure/Run-up Run-up output changes based on thecurve defined by the settings.Run-up does not change.Output is powered 0 - 10V and4 - 20 mA.Output set to 0 V.Run-up icon is displayed and can betouched.Run-up icon is not visible.Run-up related alerts and faults enabled. No run-up related alerts and faults.Remote Recall Remote Recall check box is displayedand can be touched.Remote Recall check box is grayed outand disabled.Remote recipes are re-callable. No action for changes to inputs.Alerts enabled when a recipe is loaded. No remote recipe alerts or faults.Extra Features Three additional pattern features areavailable: Random Dotted, Autodot, andContinuousIncludes other added features.No additional pattern types or addedfeatures are available.