Using the Menus 5-17Part 1124631_01E 2015 Nordson CorporationPressure Run-upUse this screen to set the two-point linear pressure curve. This setting allowsthe pattern controller to accurately regulate the system pressure to maintainproper adhesive volume during line speed changes.128467359Figure 5-14 Pressure Run up menu1. Maximum Line Pressure (percent)2. Pressure Setting in percent forend points (items 5 or 6 inFigure 5-14)3. Pressure point settingIncrease/Decrease4. Minimum Pressure (percent)5. Set point 1 (unselected)6. Set point 2 (selected)7. Display graph8. Line speed for correspondingpressure point setting(items 5 or 6 in Figure 5-14)9. Set line1. Tap Maximum Line Pressure to open the numeric keypad, assign themaximum pressure cutoff limit.2. Tap Minimum Line Pressure to open the numeric keypad to set theminimum line pressure cutoff limit.NOTE: The relationship of the pressure output and the line speedappears in the display graph.3. Select upper pressure point (see item 5 in Figure 5-14) and enterpressure (%) at the corresponding line speed.4. If a lower pressure point is desired, tap a lower pressure point (see item 6in Figure 5-14) and enter pressure and line speed in percent.