Connecting Alarms2-6 296-1011-202 Rel. 5.0, Doc. Rev. 02.01CVX 600 Hardware Installation GuideProcedureTo connect alarms to the terminal block, follow these steps:Step Action1 Select the terminals you want to use for the audible or visual alarm.2 Use a small flat-tip screwdriver to loosen the two terminal screws for eachalarm device you want to connect. For example, if you want to connect anaudible alarm for a critical condition, loosen the terminal screws for theterminals labeled Crit(ical) and Ret(urn).3 Use a wire stripper to remove approximately 1/2 inch of insulation from thewires.4 Insert the wires into the terminals and tighten the screws to 1 to 2 in-lb using a1/16-inch flat-tip screwdriver.5 Connect the other end of the wires to the alarm device.Tighten screws to1 to 2 in-lb, using a1/16-inch flat-tipscrewdriver.Remove 1/2 inchof wire insulation.Connect wiresto alarm device.CVX-0184CTighten screws to 1 to 2 in-lbusing a 1/16-inch flat-tipscrewdriver.Remove 1/2 inchof insulation.Connect wiresto alarm device.SystemOC3/STM1ConsoleOC3 /STM1-1VisualAlarmsAudibleCritRetMajRetMinRetCritRetMajRetMinRetRXTXOptical SCC-II-LTMSCC-RLTMSystemRedundantConsoleOC3/STM1-1VisualAlarmsAudibleCritRetMajRetMinRetCritRetMajRetMinRetRX TX