Technical Product Manual - DCT1900Installation Instructions, Modular Cabinet – REX-BAS9021 or BDVNB 101 01/2Install-DCT1900/R8/mw 4-1© 2000-2005CHAPTER 4Modular Cabinet – REX-BAS9021 or BDVNB 101 01/2or BDVNB 101 01/34.1 Contents of the BoxThe cardboard box in which the Modular Cabinet is shipped contains the cabinet itself and thefollowing material:z 1 mounting bracket.z a bag with modular cabinet mounting material:- cabinet mounting material:- screws (∅5 30),- tie–wraps,- M3 x 6 screws with torx heads for cable clamps,- M4 x 6 screws with torx heads and washers for protective ground cable.z labelsNote:The bag may contain more material than actually needed.4.2 Fuses4.2.1 Modular Cabinet BDVNB 101 01/2 and BDVNB 101 01/03 (R2 & R3)z Has 4 fusesz 2 fuses located on the MCCB on the bottom of the cabinet (Figure 4-2)Replace these (4) fuses only with UL listed 250V 15A fuse.Ascom Part Number: 70061001234.2.2 Modular Cabinet REX-BAS9021, REX-BAS9021A,REX-BAS9021/1B, REX-BAS9021/4B, BDVNB 101 01/3 (R4)z Has 6 fusesz 2 Fuses located on the MCCB on the botom of the cabinet (Figure 4-2)z 2 Fuses located on the bottom of the new power switch bracket (Figure 4-3)Replace these (4) fuses only with UL listed 250V 15A fuses.z 2 fuses located on the top of the new power switch bracket (Figure 4-3)Replace these (2) fuses only with the UL listed 250V 3A fuses.These fuses are common parts and maybe purchased from various vendors.