C-Series IM 1 MAY 201413.5 SETUP SCREEN 1To change Time and/orDate: Press the appropriateButton and enter the date as:xx/xx/xxxx or the time asxx:xx:xx (24 hour clock).Press to return to theSETUP 1 screen.Press to access User Configuration to change the usernames, passwords and auto-logoff times. See 13.3 on page 23. You can assign specific personnel or personnel levels for each ofthe access levels.All items on this page are accessible to be changes by a level 2 or higher user. The arrow to goto the second setup page will only appear for level 3 and higher users.SYSTEM OPTIONSEnable/Disable Scrap Mode – Press this button to Enable Scrap Mode.Imperial/Metric Units – Press this button to toggle the display unitsbetween English and Metric.AT END OF BOXCount Triggers - Triggers change in machine operation when part countreaches end of box and production. Is the same function as on the CounterScreen.PRODUCTION OUTPUTS 1 - There are two dry contact outputs supplied inthe control panel. Q0.0 corresponds to Production Output 2 and Q0.1corresponds to Production Output 1. They can be configured to trigger onmany events including Part Cut, Box Change, Production Done, Running,Run Product, Run Scrap, Stopped or Faulted. The signal can be delayedand held for a user settable amount of time. They are not high speedresponse signals. There is a typical lag of about 30 ms with an error of +/-10 ms. If a higher speed,more precise output is required, option NC8016 shown on schematics is required. Sales must becontacted to ensure the proper form of the output device.LENGTH DISPLAY HOLD TIME - This value determines how long thedisplay will show the last cut length before showing the accumulated lengthof the next part. Set it to zero to always show only the last cut length. It isrecommended to be set to at least 500ms. Parts that are cut faster than 500ms may be difficult tosee no matter the setting.11223329© 2015 NOVATEC Inc. All Rights Reserved Document: C-Series 7 MAY 2015