C-Series IM 1 MAY 201413.7 SETUP Screen 3All items on this page require setup authorization except for Exit HMI and background color.PROCESS LIMITS – Determine the blade speed limits and the points atwhich the cutter will switch between On Demand and Continuous Mode.Max Cut Rate Demand – This determines the minimum time between onDemand cuts. It also determines when the system should switch tocontinuous mode.• Min Blade Speed Demand – Sets the minimum speed that can beentered as the On Demand blade speed on the recipe screen.Min Blade Speed Cont – Sets the minimum permissible RPM of theblade in continuous mode. Typically this is set to a value which can still give a good cut to theproduct.Max On Demand Blade Speed – This sets the maximum blade speed for On Demand cutting. Thiswill be limited by the max motor speed and is typically set by NOVATEC so that the drive does notfault when accelerating and decelerating and the overall system can handle the forces of the blademotion.Note: It is possible to make settings where there are line speeds that cannot be handled by MaxOn Demand CPM or Minimum Continuous Mode blade speed.The Max continuous speed is the max speed of the motor and the gear box. It is possible to runthe continuous speed so fast that when it stops or transitions to On Demand Mode, the drivefaults.32© 2015 NOVATEC Inc. All Rights Reserved Document: C-Series 7 MAY 2015