33311Image density is too highImages are stainedImages are blurredItem to be checked Countermeasure Reference pageIs the level of the image densityset suitably?Use the manual density buttonsor the background adjustmentfunction to adjust the imagedensity properly.P.119 “6.Copy Density Adjust-ment”, P.122 “1.BackgroundAdjustment”Item to be checked Countermeasure Reference pageIs the Reversing Automatic Doc-ument Feeder (optional)securely closed?Close the cover or feeder prop-erly to shut out any outer light.P.56 “1.Setting Originals”Are the platen sheet, OriginalCover and scanning area dirty?Clean them up. P.330 “1.Daily Inspection”Is the image density set prop-erly?Adjust the image density prop-erly with the [AUTO] button ormanual density buttons.P.119 “6.Copy Density Adjust-ment”Are 2-sided originals used? As the other side of the originalscan be seen, adjust the imagedensity properly (lighter) withthe background adjustmentfunction.P.122 “1.Background Adjust-ment”Are originals with high transpar-ency used?Place a blank sheet of paperwith originals of the same sizeor larger over the original.P.58 “Sheet originals”Item to be checked Countermeasure Reference pageDoes the entire original lie prop-erly on the surface of the glass?Place the original on the glass,and then close the ReversingAutomatic Document Feeder(optional) firmly.-Is the paper moist? Replace it with new paper. -