41316401TH Rev.9 25 /Oki Data CONFIDENTIALCG376F552EE1 DB2.3.4 Control Panel Assy/ Control Panel Bezel/ LED Control PWB/ Toner Sensors/ Stacker Full Sensor/Control Panel/ Control Panel Tape Harness/ Eject Rollers(1) Detach the control panel bezel placed in the control panel Assy 2.(2) Remove the screw 1 to demount the control panel Assy 2.(3) Detach the control panel tape harness D.(4) Remove the top cover unit (see section 2.3.3).(5) Unscrew the four screws 3 to remove the earth plate 4.(6) Remove the two screws 5, unhook all the connectors 6 and demount the LED control PWB 7.(7) Remove the screw 8.(8) Disengage the four claws to demount the toner sensor B.(9) Demount the stacker full sensor C.(10) Demount the exit rollers E.(11) Detach the LED harnesses, K, Y, M and C F.(12) Detach the top cover inner frame Assy G.Figure 2-3-4 Control Panel Assy/ Control Panel Bezel/ LED Control PWB/ Toner Sensors/ StackerFull Sensor/ Control Panel/ Control Panel Tape Harness/ Eject Rollers