45850101TH Rev.1 4-21Oki Data CONFIDENTIAL4. REPLACEMENT OF PARTSLock-leverGuide-Assy-Exit(Lower)Portion A4.2.10.7 ADF-Assy(1) Open the ADF-unit, and open the Guide-Assy-Exit(Lower) by to rotate the locklever. Subsequently, bent the post of the Guide-Assy-Exit(Lower) at portion A, andrelease the Guide-Assy-Exit(Lower).(2) Remove the four claws and remove the Cover-front(Upper) ① .(3) Remove a screw (silver, No:42920406) ② and remove the ADF board ③ .(4) Remove the four screws (black, No:42932706) ④ and remove the ADF-assy ⑤ .(5) Remove the three claws and Remove the Cover-stacker(ADF) ⑥ and remove theGuide-assy-exit(Sub) ⑦ .ClawClawClawClawClaw