IV - 62Section IV - TCP/IPOKI OkiLAN 6010e User’s GuideUnable to Assign IP AddressGleaningIf you ping the device and are not getting a response,the glean is not working. Check the following possibleproblems:• Verify the ARP table contains the correcthardware and IP address by running the‘arp –a’ command.• If you are getting a response, but theOkiLAN 6010e LED is still blinking green,power down the print server and try the pingagain. There might be a different deviceanswering to the ping.• Verify the OkiLAN 6010e is on the samesubnet as the computer running the ping.• The glean will not work if the OkiLAN6010e has already defaulted to an IP addresstwo minutes after power up. The LED willturn solid green and the device will print aconfiguration page. Power cycle the deviceand try the glean again.