6.1 High-level Instructions Used for EtherNet/IP Control6-9Example 11) When specifying the reading of cyclic communication abnormal node tableWhen the maximum registered node number is "0", only the value of [D] is updated and the values after [D+1] are notupdated.[S1]... "EIP" [S2]... "ERR" [D]...WR100ValueWR100 0 Max. registration node numberExample 12) When specifying the reading of RUN/IDLE bit monitor (PLC standby flag)[S1]... "EIP" [S2]... "PLC" [D]...WR200ValueWR200 9 Max. registration node numberWR201 0000 0001 1111 1111 RUN/IDLE bit monitor (Node nos. 1 to 9)Example 13) When specifying the reading of RUN/IDLE bit monitor (PLC standby flag)[S1]... "EIP" [S2]... "PLC" [D]...WR200When the maximum registered node number is "0", only the value of [D] is updated and the values after [D+1] are notupdated.ValueWR200 0 Max. registration node number Flag operationName DescriptionHold error (R9007)Latest error (R9008)Set when the read area is out of the range.Set when the read type (S1) is set to an item other than "IPv4" or "EIP".Set when the target to be read (S2) is set to an item other than “MAC”, “CONNECT”,“ALL”, “NODE”, “NORMAL”, “STOP”, “ERR” or “PLC”.Set when a combination other than the combinations listed in the restrictions oncombination is specified for the type (S1) and target (S2) to be read.Set when the unit specified by F469 UNITSEL is not the Ethernet communication.Set when executed in an interrupt program.