23Error and warning displaysIf an error has occurred in the monitor for some reason, an error or warning display will appear on the screen.± CRCC error≥ When this error appearsWhen the SDI signals contain an error, the CRCC error display appears on the screen.When a menu is displayed, the error is indicated in the menu area. At all other times, it is indicated on the statusdisplay. However, only the error will be displayed when 3SEC OFF or OFF has been selected as the STATUSDISPLAY item setting on the OSD screen. On the other hand, if OFF has been selected as the CRCC MESSAGEitem setting on the OSD screen, the error will not be displayed even when it has been detected.≥ CountermeasureCheck the input signals and connection statuses.± Inverter error≥ When this error appearsIf trouble has occurred in the inverter which controls the brightness of the backlight, the backlight is turned off, and allthe lamps by the sides of the image controls and tally lamps flash at 1-second intervals.≥ CountermeasureTurn off the power and turn it back on. If the error display persists, contact a Panasonic service center.± Low remaining battery charge warning/error≥ When this warning/error appearsIf the battery voltage is 10.5V to 11.3V:(If the remaining charge is less than 10% when an Anton Bauer digital battery is being used)> The remaining battery charge and voltage are displayed on the screen, and the display flashes.If the battery voltage is less than 10.5V:> “END BATTERY” appears on screen in red for about three seconds, and the power is turned off.≥ CountermeasureReplace the battery with one containing a sufficient charge.REMOTE specificationsRS-232C connectorFor the RS-232C connector pin layout and connections,refer to the figure below and tables on the right.For details on systems that use the RS-232C connector,consult with your dealer a Panasonic Service Center.Pin no.123456789SignalPC side BT-LH900P sideRS-232CNCTXDRXDNCGNDDSRRTSCTSNCPin no.123456789SignalNCTXDRXDNCGNDDSRRTSCTSNC1695 4 3 28 7