Values of T1, T2, and T3 depend on remote control setting temperature, as shown in below table. After the adjustment of T1, T2and T3 values, the operation mode for that particular environment and remote control setting is judged and performed, based onthe above operation mode chart, every 30 minutes.Remote Control Setting Temperature (°C) T1 T2 T316 ~ 18 +10 +8 -519 ~ 22 +8 +7 -723 ~ 26 +7 +6 -727 ~ 30 +6 +5 -8There is a temperature shifting on T1, T2, and T3 if the operation mode judged is changed from Cooling/Soft Dry to Heating or viceverse.Operation Mode change from Temperature shifts (°C)Cooling/Soft Dry → Heating -2Heating → Cooling/Soft Dry +2Example of operation mode chart adjustment:From the above table, if remote control setting temperature = 25,T1 = 25 + 7 = 32; T2 = 25 + 6 = 31; T3 = 25 - 7 = 18The operation mode chart for this example is as shown in below figure and the operation mode to be performed will depend onindoor intake air temperature and outdoor air temperature at the time when the judgment is made.8.1.7. Indoor Fan Motor OperationA. Basic Rotation Speed (rpm)• Required rotation speed for fan is set to respond to the remote control setting (10 rpm unit)[Cooling, Dry, Fan]Remote Control — O O O O O — — —Tab (rpm) SHI Hi Me+ Me Me- Lo Lo- SLo SSLoE24DK 1670 1580 1480 1390 1290 1200 930 840 630[Heating]Remote Control — O O O O O — — —Tab (rpm) SSHI SHi Me+ Me Me- Lo Lo- SLo SSLoE24DK 1690 1690 1590 1500 1400 1310 930 400 30018CS-E24DKE CU-E24DKE