8.1.14. Auto Restart Control1. When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within three to fourminutes (there are 10 patterns between 2 minutes 58 seconds and 3 minutes 52 seconds to be selected randomly) after powersupply resumes.2. This type of control is not applicable during ON/OFF Timer setting.8.1.15. Indication PanelLED POWER TIMER QUIET POWERFUL ION ALLERGENBUSTERColor Green Orange Orange Orange Green BlueLight ON Operation ON Timer Setting ON Quiet Mode ON Powerful Mode ON Ion Mode ON Operation ONLight OFF Operation OFF Timer Setting OFF Quiet Mode OFF Powerful Mode OFF Ion Mode OFF Operation OFFNote:• If POWER LED is blinking, the possible operations of the unit are Hot Start, during Deice operation, operation modejudgment, or delay ON timer sampling.• If Timer LED is blinking, there is an abnormality operation occurs.• If Ionizer, LED is blinking, there is an abnormality of Ionizer occurs.8.1.16. Auto Operation Switch1. When the switch is pressed between 0 to 5 seconds, Auto Mode operation starts to function.2. When the switch is pressed between 5 to 8 seconds, the unit is forced to operate in Cooling Mode.3. When the switch is pressed between 8 to 11 seconds, the unit will enter forced Heating Mode standby. Press timer decrementbutton for 5S for the unit to operate in Heating Mode.4. When the switch is pressed between 11 to 16 seconds and together with the signal from remote control (timer decrement buttonfor 5S), the unit can be changed to different controlling setting (4 type of transmission codes).5. When the switch is pressed between 16 to 21 seconds, either “H14” error detection selection mode or the remote control signalreceiving sound can be cancelled or turned on.28CS-E24DKE CU-E24DKE