12319. Technical DataTechnical data provided are based on the air conditioner running under free frequency.19.1 Cool Mode Performance DataUnit setting: Standard piping length, Hi Fan, Cool mode at 16°CVoltage: 230V19.1.1 CS-NZ9SKE/CU-NZ9SKE CS-QZ9SKE/CU-QZ9SKEIndoor (°C) Outdoor DB (°C)DB WB 16 25 35TC SHC IP TC SHC IP TC SHC IP27 19.0 2841 2329 284 2669 2214 387 2500 2102 51022.0 3170 1762 269 2940 1678 378 2583 1538 50423 15.7 2698 2262 298 2497 2179 394 2226 2011 50918.4 2921 1796 289 2660 1666 389 2389 1558 50920 13.3 1926 1740 171 1834 1657 285 1743 1574 44715.8 1941 1526 158 2398 1615 391 2139 1510 506(Dry bulb value based on 46% humidity)19.1.2 CS-NZ12SKE/CU-NZ12SKEIndoor (°C) Outdoor DB (°C)DB WB 16 25 35TC SHC IP TC SHC IP TC SHC IP27 19.0 3977 2765 479 3737 2630 653 3500 2496 86022.0 4439 2093 454 4116 1992 638 3616 1826 85123 15.7 3777 2687 503 3496 2588 664 3116 2464 85818.4 4090 2133 488 3723 1979 656 3344 1850 85820 13.3 2378 1899 217 2567 2206 480 2440 2132 75415.8 2393 1596 204 3357 1917 659 2995 1793 854(Dry bulb value based on 46% humidity)TC - Total Cooling Capacity (W)SHC - Sensible Heat Capacity (W)IP - Input Power (W)