3511.2.4 Connect the Cable to the Indoor Unit1. The inside and outside connection cable canbe connected without removing the front grille.2. Unscrew the conduit cover and fix the conduitconnector to conduit cover with lock nut, thensecure it against chassis.3. Connection cable between indoor unit andoutdoor unit should be UL listed or CSAapproved 4 conductor wires minimum AWG16in accordance with local electric codes.o Ensure the colour of wires of outdoor unitand terminal number are the same as theindoor's repectively.Terminals on the indoor unit 1 2 3Colour of wires (connection cable)Terminals on the outdoor uni t 1 2 3WARNINGThis equipment must be properly earthed.o Earth lead wire shall be Yellow/Green(Y/G) in colour and shall be longer thanother lead wires as shown in the figure forelectrical safety in case of the slipping.ChassisConduitConnectorConduitCoverLock NutRear Side of Indoor UnitHolderIndoor andoutdoorconnectioncableTerminalBoardEarth wirelonger thanothersAC wiresfor safetyreason11.2.4.1 Wire Stripping, Connecting RequirementWire stripping7/32” (5 mm)or moreConductorover insertedNo loose strandwhen insertedIndoor/outdoorconnectionterminal board10 ± 1 mm13/32” ± 1/16” Conductorfully insertedConductor notfully inserted(gap between wires) ACCEPT PROHIBITED PROHIBITEDWARNINGRISK OF FIREJOINING OF WIRESMAY CAUSEOVERHEATINGAND FIRE.ORORORUse complete wire without joining.Use approved socket and plug with earth pin.Wire connection in this area must follow tonational wiring rules.Do not joint wires