13220. Technical DataTechnical data provided are based on the air conditioner running under free frequency.20.1 Cool Mode Performance DataUnit setting: Standard piping length, Hi Fan, Cool mode at 16°CVoltage: 230V20.1.1 CS-TZ20TKEW/CU-TZ20TKEIndoor (°C) Outdoor DB (°C)DB WB -10 -7 0 5 16 25 35TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP27 19 2228 2052 374 2239 2065 372 2247 2035 374 2184 2047 435 2458 2210 297 2291 2160 395 2000 1993 51022 2458 1651 379 2418 1650 411 2430 1646 400 2528 1688 347 2707 1795 285 2511 1696 390 2239 1590 51223 15.7 1990 1970 400 2005 1985 383 1985 1965 419 1997 1977 408 2215 2192 307 2054 2034 398 1817 1799 51018.4 2200 1638 374 2216 1635 362 2231 1645 374 2147 1617 426 2354 1712 300 2241 1689 395 2014 1584 51120 13.3 1767 1750 458 1751 1734 383 1891 1872 401 1834 1816 418 2083 2063 314 1892 1873 400 1688 1671 50915.8 2008 1616 400 2002 1613 379 1991 1593 420 1952 1570 439 2191 1702 307 2041 1637 398 1831 1539 510(Dry bulb value based on 46% humidity)20.1.2 CS-TZ25TKEW/CU-TZ25TKEIndoor (°C) Outdoor DB (°C)DB WB -10 -7 0 5 16 25 35TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP27 19 2646 2235 484 2658 2249 481 2669 2216 484 2593 2230 564 2919 2407 385 2721 2353 511 2500 2171 66022 2919 1798 490 2872 1797 532 2886 1792 518 3002 1838 449 3215 1955 368 2982 1847 504 2659 1732 66323 15.7 2363 2340 518 2381 2203 495 2357 2183 542 2372 2348 528 2630 2604 397 2439 2254 515 2158 2136 66018.4 2613 1784 484 2631 1780 468 2649 1792 484 2550 1761 552 2795 1864 388 2661 1839 511 2392 1725 66120 13.3 2099 2078 593 2080 2059 495 2245 2169 518 2178 2093 541 2474 2449 406 2247 2224 517 2004 1984 65915.8 2384 1760 517 2378 1756 490 2364 1735 544 2318 1710 568 2601 1853 397 2423 1783 515 2174 1676 661(Dry bulb value based on 46% humidity)20.1.3 CS-TZ35TKEW/CU-TZ35TKEIndoor (°C) Outdoor DB (°C)DB WB -10 -7 0 5 16 25 35TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP27 19 3821 2954 733 3839 2973 729 3854 2930 733 3745 2947 854 4215 3181 583 3930 3110 774 3500 2870 100022 4215 2377 742 4148 2375 807 4168 2369 784 4335 2430 680 4643 2584 558 4306 2442 764 3840 2289 100423 15.7 3413 3379 785 3438 2913 750 3404 2885 821 3425 3391 801 3798 3760 602 3523 2980 781 3116 2855 100018.4 3774 2358 734 3800 2353 710 3826 2369 734 3682 2327 836 4037 2464 588 3843 2432 775 3454 2281 100120 13.3 3031 3001 898 3004 2700 750 3242 2867 785 3146 2767 820 3573 3537 616 3245 2907 784 2895 2723 99815.8 3443 2326 784 3434 2322 743 3414 2293 824 3348 2260 861 3757 2450 601 3500 2357 780 3140 2215 1001(Dry bulb value based on 46% humidity)AMP Air Conditioningwww.ampair.co.uk | sales@ampair.co.uk