4512.2.3 Indoor Unit Installation● Do not turn over the unit without it’s shock absorber during pull out the piping.It may cause intake grille damage.● Use shock absorber during pull out the piping to protect the intake grille from damage.PipingIntake grilleShock absorberPipingpulloutthepipingpulloutthepiping12.2.3.1 For the Right Rear PipingInstall the Indoor UnitPull out the Indoor pipingStep-2Secure the Indoor UnitInsert the connection cableStep-1Step-3Step-412.2.3.2 For the Right and RightBottom PipingInstall the Indoor UnitPull out the Indoor pipingStep-2Insert the connection cableSecure the Indoor UnitStep-1Step-3Step-412.2.3.3 For the Embedded Piping• Use a spring bender or equivalent to bend the piping so that the piping is notcrushed.• When determining the dimensions of the piping, slide the unit all the way to theleft on the installation plate.• Refer to the section “Cutting and flaring the piping”.Bend the embedded pipingCut and flare the embedded pipingReplace the drain hosePull the connection cable into Indoor Unit• The inside and outside connection cable can be connected without removingthe front grille.Step-1Step-2Step-3Step-4• Please refer to “Connecting the piping” column in outdoor unit section.(Below steps are done after connecting the outdoor piping and gas-leakageconfirmation.)Connect the piping• Please refer to “Insulation of piping connection” column as mentioned inindoor/outdoor unit installation.Install the Indoor UnitSecure the Indoor UnitInsulate and finish the pipingStep-5Step-6Step-7Step-8Right Rear pipingHow to keep the coverIn case of the cover is cut, keep the cover at the rearof chassis as shown in the illustration for futurereinstallation.(Left, right and 2 bottom covers for piping.)Install the indoor unitHook the indoor unit onto the upperportion of installation plate. (Engagethe indoor unit with the upper edgeof the installation plate). Ensure thehooks are properly seated on theinstallation plate by moving it in leftand right.Secure the Indoor UnitRight and Right Bottom pipingInsert the connection cablePress the lower left and right side of the unitagainst the installation plate until hooksengages with their slot (sound click).Cover for thebottom pipingCover for thebottom pipingTape it with piping in aposition as mentioned inFig. below.Cover forthe rightpipingPipingDrainhoseCover forthe leftpipingCover forthe bottompipingTape it with piping in aposition as mentioned inFig. below.Cover for theright pipingPipingDrain hoseCover forthe leftpipingDrain hoseSleeve forpiping holeIndoor unitHooks atinstallationplatePipingCover for pipingGuidesurface ConnectioncableAbout70 – 80 mmConnection cableGas side pipingLiquid side pipingDrain hoseInstallationplateUnit’s hookTo take out the unit, push the marking atthe bottom unit, and pull it slightly towards you todisengage the hooks from the unit.gnikram(This can be used for left rear piping and left bottompiping also.)AMP Air Conditioningwww.ampair.co.uk | sales@ampair.co.uk