7914.6 Sleep Mode OperationSLEEPTo maximise comfort while sleeping(CANCEL) This operation provides you with a comfortable environment while sleeping. It will automatically adjust the sleeppattern temperature during the activation period. The indoor unit indicator will dim when this operation is activated. This is not applicable if the indicator brightnesshas been manually dimmed. This operation is incorporated with the activation timer (0.5, 1, 2, 3, 4, 5, 6, 7, 8 or 9 hours). This operation can be set together with single timer or twin timer. Sleep operation has the priority over OFF timer. This operation can be cancelled by pressing the respective button when the sleep timer reaches 0.0h.14.7 Auto Restart Control When the power supply is cut off during the operation of air conditioner, the compressor will re-operate withinthree to four minutes (there are 10 patterns between 2 minutes 58 seconds and 3 minutes 52 seconds to beselected randomly) after power supply resumes. This type of control is not applicable during ON/OFF Timer setting. This control can be omitted by open the circuit of JP1 at indoor unit printed circuit board.14.8 Indication PanelLED POWER TIMERColor Green OrangeLight ON Operation ON Timer Setting ONLight OFF Operation OFF Timer Setting OFFNote: If POWER LED is blinking, the possible operation of the unit are Hot Start, during Deice operation, operationmode judgment, or ON timer sampling. If Timer LED is blinking, there is an abnormality operation occurs.14.9 Quiet Operation (Cooling Mode/Cooling Area of Dry Mode)A. PurposeTo provide quiet cooling operation compare to normal operation.B. Control conditiona. Quiet operation start conditiono When “POWERFUL/QUIET” button at remote control is pressed twice.b. Quiet operation stop condition1 When one of the following conditions is satisfied, quiet operation stops:a. POWERFUL/QUIET button is pressed again.b. Stop by OFF/ON switch.c. Timer “off” activates.2 When quiet operation is stopped, operation is shifted to normal operation with previous setting.3 When fan speed is changed, quiet operation is shifted to quiet operation of the new fan speed.4 When operation mode is changed, quiet operation is shifted to quiet operation of the new mode.5 During quiet operation, if timer “on” activates, quiet operation maintains.6 After off, when on back, quiet operation is not memorized.C. Control contents1 Fan speed is changed from normal setting to quiet setting of respective fan speed.2 Fan speed for quiet operation is reduced from setting fan speed.AMP Air Conditioningwww.ampair.co.uk | sales@ampair.co.uk