93. SpecificationsModel Indoor CS-TZ20TKEW CS-TZ25TKEWOutdoor CU-TZ20TKE CU-TZ25TKEPerformance Test Condition EUROVENT EUROVENTPower Supply Phase, Hz Single, 50 Single, 50V 230 230Min. Mid. Max. Min. Mid. Max.CoolingCapacitykW 0.75 2.00 2.40 0.85 2.50 3.00BTU/h 2560 6820 8180 2900 8530 10200Kcal/h 650 1720 2060 730 2150 2580Running Current A – 2.30 – – 2.95 –Input Power W 250 510 620 250 660 890Annual Consumption kWh – 255 – – 330 –EERW/W 3.00 3.92 3.87 3.40 3.79 3.37BTU/hW 10.24 13.37 13.19 11.60 12.92 11.46Kcal/hW 2.60 3.37 3.32 2.92 3.26 2.90ErPPdesign kW 2.0 2.5SEER (W/W) 6.4 6.4AnnualConsumption kWh 109 137Class A++ A++Power Factor % – 96 – – 97 –Indoor Noise (H / L / QLo) dB-A 37 / 25 / 20 40 / 26 / 20Power Level dB 53 / 41 / 36 56 / 42 / 36Outdoor Noise (H / L) dB-A 46 / – 47 / –Power Level dB 61 / – 62 / –HeatingCapacitykW 0.70 2.70 3.60 0.80 3.30 4.10BTU/h 2390 9210 12300 2730 11300 14000Kcal/h 600 2320 3100 690 2840 3530Running Current A – 3.00 – – 3.55 –Input Power W 185 670 1.04k 195 800 1.13kCOPW/W 3.78 4.03 3.46 4.10 4.13 3.63BTU/hW 12.92 13.75 11.83 14.00 14.13 12.39Kcal/hW 3.24 3.46 2.98 3.54 3.55 3.12ErPPdesign kW 1.9 2.4Tbivalent °C -10 -10SCOP (W/W) 4.1 4.2AnnualConsumption kWh 649 800Class A+ A+Power Factor % – 97 – – 98 –Indoor Noise (H / L / QLo) dB-A 38 / 26 / 22 40 / 27 / 22Power Level dB 54 / 42 / 38 56 / 43 / 38Outdoor Noise (H / L) dB-A 47 / – 48 / –Power Level dB 62 / – 63 / –Low Temp. : Capacity (kW) / I.Power (W) / COP 2.61 / 920 / 2.84 2.97 / 1.00k / 2.97Extr Low Temp. : Capacity (kW) / I.Power (W) / COP 2.14 / 860 / 2.49 2.70 / 1.05k / 2.57Max Current (A) / Max Input Power (W) 4.6 / 1.04k 5.0 / 1.13kStarting Current (A) 3.00 3.55AMP Air Conditioningwww.ampair.co.uk | sales@ampair.co.uk