3312. Installation Instruction12.1 Select The Best Location12.1.1 Indoor Unit Do not install the unit in excessive oil fume areasuch as kitchen, workshop and etc. There should not be any heat source or steamnear the unit. There should not be any obstacles blocking the aircirculation. A place where air circulation in the room is good. A place where drainage can be easily done. A place where noise prevention is taken intoconsideration. Do not install the unit near the door way. Ensure the spaces indicated by arrows from thewall, ceiling, fence or other obstacles. Recommended installation height for indoor unitshall be at least 2.5 m.12.1.2 Outdoor Unit If an awning is built over the unit to prevent directsunlight or rain, be careful that heat radiation fromthe condenser is not obstructed. There should not be any animal or plant whichcould be affected by hot air discharged. Keep the spaces indicated by arrows from wall,ceiling, fence or other obstacles. Do not place any obstacles which may cause ashort circuit of the discharged air. If piping length is over the [piping length foradditional gas], additional refrigerant should beadded as shown in the table.ModelHorsePower(HP)Piping size Std.Length(m)Max.Elevation(m)Min.PipingLength(m)Max.PipingLength(m)AdditionalRefrigerant(g/m)PipingLengthfor add.gas (m)Gas LiquidVZ9*** 1.0HP 9.52 mm(3/8")6.35 mm(1/4") 5 12 3 15 20 7.5VZ12*** 1.5HPExample: For VZ9***If the unit is installed at 12 m distance, the quantity ofadditional refrigerant should be 40 g …. (12-10) m ×20 g/m =40 g.12.1.3 Indoor/Outdoor Unit InstallationDiagram70 mmor more50 mmor more50 mmor more(Left and rightare identical)100 mmor more200 mmor more50 mmor more300 mmor moreInstallation plateSleeve ( )Bushing-Sleeve ( )Bend the pipe asclosely on the wall aspossible, but be carefulthat it doesn’t break.Saddle ( )Additional drain hoseGas side piping ( )Connection cablePutty ( )(Gum Type Sealer)Installation parts youshould purchase ( )Liquid side piping ( )dnebottonnoitnettAnoitceridgnipiPup drainhose(Front side)RightRightRearRightbottom LeftRear Left bottomLeftIt is advisable toavoid more than 2blockage directions.For better ventilation& multiple-outdoorinstallation, pleaseconsult authorizeddealer/specialist.• Carry out insulation afterchecking for gas leaks andsecure with vinyl tape.Vinyl tapeInsulation of piping connectionsAttaching the remote control holder to the wallRemote control holder fixing screwsRemote control holderRemotecontrolVinyl tape (wide) ( )• Apply after carryingout a drainage test.• To carry out thedrainage test,remove the air filtersand pour water intothe heat exchanger.Control board coverLength of power supply cordAbout1.2 mAbout1.9 mWARNINGFlare connection onlyat outside of buildingThis illustration is for explanation purposes only.The indoor unit will actually face a different way.