7614.14 +8/10°C Operation +8/10°C operation provides heating at low setting temperature in unoccupied houses during winter for thepurpose of protecting equipments or housing appliances which may be destroyed by the extreme cold weather. This operation can be ON by pressing the +8/10°C button on the remote control. Two temperature settings are available, which are;o 8°C (Pressing TEMP down button at the remote control)o 10°C (Pressing TEMP up button at the remote control)During the operation or standby mode: The indoor fan speed will remain at Hi fan tap all the time included deice process. Powerful operation, Quiet operation, Econavi operation and Fan Speed selection are disabled. Cold draft prevention control is disabled. The vane direction can be set using remote controller. In default setting, it will operate the nanoe at the same time. Control condition;OFFOFF+8/10°CHEAT+8/10°CHEAT[TEMP ] button[TEMP ] buttonStart with the lastselected modeHEATNOTE:+8/10°C HEAT set temperature follows previously fixed set temperature (+8°C or +10°C).But after battery reset, (default condition) set temperature always start with +8°C.CautionIf the indoor temperature constantly is less than 0°C (Door, windows not close properly), the error code F11 mayoccur. This is because in open area, the indoor pipe sensor will misjudge operation condition and will give error code.