Time Delay Safety ControlAnti-Freezing ControlCompressor Reverse Rotation Protection ControlAnti-Dew Formation ControlAutomatic Fan Speed Mode8.3. Soft Dry Mode Operation•••• The unit starts cooling operation until the room temperature reaches the setting temperature set on the Remote Control, andthen Soft Dry operation will start.•••• During Soft Dry operation, the Indoor Fan will operate at Lo- speed.•••• Once room temperature reaches below Soft Dry OFF temperature. Indoor Fan, Compressor and Outdoor Fan stop for 6minutes.•••• Once the compressor stops, it will not start for 3 minutes during Cooling operation.•••• Same as Anti-Freezing Control for Cooling Mode operation. (For Soft Dry region, 6 minutes waiting is valid during compressorstops.)•••• Same as Compressor Reverse Rotation Protection Control for Cooling Mode Operation. (For Soft Dry region, 6 minutes waitingis valid during compressor stops.)•••• Same as Anti-Dew Formation Control for Cooling Mode operation.When Automatic Fan Speed is selected at Remote Control during Soft Dry operation.•••• Fan speed off and on at Lo- speed.•••• Deodorizing Control.20CS-W18CKE CU-W18CKE / CS-W24CKE CU-W24CKE