8.10. Powerful Mode OperationPurpose of this operation is to be obtain the setting temperature quickly.1. Cooling and Soft Dry Mode•••• When the Powerful Mode is set, the set temperature will be automatically decreased 3°C against the present settingtemperature (Lower temperature: 16°C). This operation automatically will be running under SHi Fan Speed (Cooling), Lo-Fan Speed (Soft Dry).•••• Vertical Airflow Direction:-In “Manual” setting, the vane will automatically shift down 10° lower than previous setting.In “Auto” setting, the vane will automatically swing up and down. However the upper and lower limit will be shifted 10°downward.2. Heating Mode•••• When the Powerful Mode is set, the set temperature will be automatically increased 3°C against the present settingtemperature (Higher temperature: 30°C).•••• The Fan Speed will shift as shown below:•••• Vertical Airflow Direction:-In “Manual” setting, the vane will automatically shift down 5° lower than previous setting.In “Auto” setting, the vane will automatically shift between upper and lower limit depending on the intake air temperature asHeating Mode, Airflow Direction Auto-Control. However the upper and lower limit will be shifted 5° downward.3. Powerful mode will operate for 15 minutes only.4. Powerful Mode will stop if:•••• Powerful mode button is pressed again.•••• Stopped by ON / OFF switch.•••• Timer-off activates.•••• Quiet mode button is pressed.•••• Operating mode button is changed.30CS-W18CKE CU-W18CKE / CS-W24CKE CU-W24CKE