Vertical Airflow Direction Auto-Control•••• When set an Airflow Direction Auto-Control with remotecontrol, the louver swings up and down as shown in thediagram.•••• The louver does not swing when the Indoor Fan Motorstops during operation at the upper limit.•••• When stopped with remote control, the discharge vent isreset, and stopped at the closing position.•••• During Anti-dew condensation prevention, Airflow DirectionAuto-control angle change from 0° - 36° to 12° - 28° underCooling and Soft Dry operation mode.Vertical Airflow Direction manual Control•••• When the manual Airflow Direction Selection Button ispressed, the automatic airflow is released and the airflowdirection louver move up and down in the range shown inthe diagram.The louver can be adjusted by pressing the button to thedesired louver position.•••• When the remote control is used to stop the operation, thedischarge vent is reset, and stopped at the closing position.•••• During Anti-dew condensation prevention, Airflow DirectionManual control angle change from 14°, 19°, 24°, 30°, 36° to16°, 18°, 20°, 22°, 24° under Cooling and Soft Dry operationmode.8.6. Random Auto Restart Control•••• If there is a power failure during air conditioner operation, operation will be automatically restarted after 3 to 4 minutes when thepower is resumed.It will start with previous operation mode and airflow direction.•••• Restart time is decided randomly using 4 parameter:-Intake air temperature, setting temperature, fan speed and Air Swing Blade position.•••• Auto Restart Control is not available when Timer is set.•••• This control can be omitted by open the circuit of JX2. (Refer Circuit Diagram)8.7. Airflow Direction Control1. There is no swinging while indoor fan motor is stopped during Cooling, Ion and Soft Dry operation.2. In Heating operation, when the piping air temperature reaches 38°C, the louver is changed from upper to lower limit position. When thepiping air temperature falls to 35°C, the louver is changed from lower to upper limit position.28CS-W18CKE CU-W18CKE / CS-W24CKE CU-W24CKE