8.11. Ionizer OperationPurposeTo provide fresh air effect to user by discharging minus Ion to air.Control Conditiona. Ionizer Only Operation.1. When air-conditioner unit is at “OFF” condition (standby) and ION operation button at remote control is pressed.Fan & ionizer on, ION LED illuminates, but power LED maintain off. (1 → 2)However, fan speed can be adjusted later by customer during this operation.Airflow direction (Horizontal Vane) control:Follow vane direction control at cooling mode.Horizontal vane can be changed by customer during ion only operation.2. Ion only operation can be off by pressed ION button again. (2 → 1)3. It can be changed to previous operated mode (Auto, Cool, Dry, Heat) + ion operation by OFF/ON switch. (2 → 4)4. During ion only operation, if power failure occur, after power resume, ionizer & air-conditioner resumes immediately.5. After error = 24 times, (about 11h 30 min.), ion & fan off with Ion LED blinks continuously.(Detail refer to Ionizer Error detection control.)b. Operation Mode + Ionizer Operation.1. Ionising Operation Start ConditionWhen air-conditioner unit is in “ON” condition (Cool, Dry, Heat, Auto mode) and ION operation button at remote control ispressed. Ionizer on & ION LED illuminates. (3 → 4)Power LED also illuminates.2. Ionising Operation Stop ConditionWhen one of the following condition is satisfied, ION operation stops.a. Stopped by ON/OFF switch.b. Timer OFF activates.c. ION operation button is pressed again.d. ION feedback signal shows error.31CS-W18CKE CU-W18CKE / CS-W24CKE CU-W24CKE