8.1.9. Airflow Direction1. There are two types of airflow, vertical airflow (directed by horizontal vane) and horizontal airflow (directed by vertical vanes).2. Control of airflow direction can be automatic (angles of direction is determined by operation mode, heat exchanger temperatureand intake air temperature) and manual (angles of direction can be adjusted using remote control).Vertical AirflowOperation Mode Airflow Direction Vane Angle (°)1 2 3 4 5Heating Auto with Heat Exchanger 17Temperature 587Manual 7 17 33 49 67Cooling, Soft Dry and Fan, Ion, O 2 Auto 7 ~ 37Manual 7 17 25 33 41Mode Judgement in Auto Auto 7Manual 7 17 25 33 411. Automatic vertical airflow direction can be set using remote control; the vane swings up and down within the angles as statedabove. For heating mode operation, the angle of the vane depends on the indoor heat exchanger temperature as Figure 1below. When the air conditioner is stopped using remote control, the vane will shift to close position.2. Manual vertical airflow direction can be set using remote control; the angles of the vane are as stated above and thepositions of the vane are as Figure 2 below. When the air conditioner is stopped using remote control, the vane will shift toclose position.Horizontal Airflow1. Automatic horizontal airflow direction can be set using remote control; the vane swings left and right within the angles asstated below. For heating mode operation, the angle of the vane depends on the indoor heat exchanger temperature asFigure 1 below.Operation Mode Vane Angle (°)Heating, with heat exchanger temperature A 55 ~ 125B 90Cooling, Soft Dry and Fan, Ion, O 2 55 ~ 12524CS-XE9CKE CU-XE9CKE / CS-XE12CKE CU-XE12CKEPanasonic ilmalämpöpumput korjaa ja huoltaa pääkaupunkiseudulla: Jäähdytinpalvelu RefGroup Oywww.ilmalämpöpumput.com