8.1.9.1. Vertical AirflowOperation Mode Airflow Direction Vane Angle (°)1 2 3 4 5Heating Auto with Heat Exchanger A Upward fix 3Temperature B Downward fix 64C Upward fix 3D Downward fix 3Manual 3 17 33 49 63Cooling, Soft Dry and Ion Auto 8 ~ 36Manual 8 15 22 30 36Mode Judgment in Auto Auto 8Manual 8 15 22 30 361. Automatic vertical airflow direction can be set using remote control; the vane swings up and down within the angles as statedabove. For heating mode operation, the angle of the vane depends on the indoor heat exchanger temperature as Figure 1below. When the air conditioner is stopped using remote control, the vane will shift to close position.2. Manual vertical airflow direction can be set using remote control; the angles of the vane are as stated above and the positionsof the vane are as Figure 2 below. When the air conditioner is stopped using remote control, the vane will shift to close position.8.1.9.2. Horizontal Airflow1. Automatic horizontal airflow direction can be set using remote control; the vane swings left and right within the angles as statedbelow. For heating mode operation, the angle of the vane depends on the indoor heat exchanger temperature as Figure 1below.Operation Mode Vane Angle (°)Heating, with heat exchanger temperature A 65 ~ 115B 90Cooling, Soft Dry and Ion 65 ~ 1152. Manual horizontal airflow direction can be set using remote control; the angles of the vane are as stated below and the positionsof the vane are as Figure 2 above.Pattern 1 2 3 4 5Airflow DirectionPatterns at RemoteControlVane Angle (°) 90 65 78 102 11529CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKEThis document is protected (secured) by www.nettovarmepumpar.se