2.2 Switch Settings2-32.2 Switch Settings Unit number selector (For W mode / W2 mode)02531487960253148796UNITNO.W mode W2 modePLC link (Corresponding unit numbers) 01-16 01-32Data transfer (Corresponding unit numbers) 01-32 01-64 (Note 2)(Note 1) The factory default setting is "00". When using tool software or user program to set unit numbers, set “00”.(Note 2): It shows the range of settable unit numbers. The maximum number of units that can be actually used is 32. Slave unit number display selector (For F mode)Switches the slave unit number display of the operation monitor LEDs.Item Settings1-16 Displays the connected units nos. 1 to 16.17-32 Displays the connected units nos. 1 to 32. Mode setting switchON OFF1234Item OperationW mode W2 mode F modeOperation mode 1 OFF: PLC link modeON: Non-PLC link modeOFF: Stops communication in case ofcommunication error.ON: Continues communication incase of communication error.Mode setting 2 OFF ON ON3 OFF OFF ONBaud rate 4 500 kbps fixed OFF: 500 kbpsON: 250 kbps 500 kbps fixed(Note 1): Be sure the power is off when changing the switches.(Note 2): All the switches are set to OFF at the factory.